Electrical Wiring For Models 222, 342, & 462 - Fostoria 222 Series Manual

2 and 3 lamp units; overhead electric infrared heater
Table of Contents

Advertisement

ELECTRICAL SHOCK HAZARD
This fixture is equipped with 4 high-temperature silicone
lead wires to accommodate either single phase or three
phase electrical service. They are shipped wire-tied
together. Remove the wire-tie before making electrical
connections.
Wiring connections should always be made through
one of the knockouts in the top wire channel. Consult
the factory, or a qualified electrician for details on
staging.
Wires in wiring channel are identified with wire markers.
Markers indicate lamp number.
Supply wires must be copper and rated for at least 90º
C. Wire connectors should also have a minimum rating
of 90º C.
For
use
in
TOTALLY
APPLICATIONS refer to page 10.
SINGLE-STAGE WIRING Connect both wires from
one end of heater to L1 and the remaining wires from
the other end to L2 in the control panel.
L1
ISSUE DATE 10-09-03
WIRING FOR UNITS WITH (2) LAMPS
• Serious injury or death may
occur.
• Disconnect from electrical
supply before installing or
servicing this heater.
• This appliance must be
connected to a properly
bonded (grounded)
electrical source.
EXPOSED
OUTDOOR
LAMP NO. 1
LAMP NO. 2
REV. DATE 12/17
TWO-STAGE WIRING
Two-stage operation allows one or both lamps in the heater(s)
to be energized, depending on the signal from an appropriate
two-stage control device (e.g. two-stage thermostat). This will
allow the heater(s) to operate at 50% on, 100% on, or 100% off;
instead of limiting the operation to 100% on or 100% off.
Two circuits are required for two-stage wiring.
For two-stage operation connect L1 & L2 of circuit #1 to lamp #1
and connect L1 & L2 of circuit #2 to lamp #2 as illustrated below.
L1
L1
Common component layout for controlling
Fostoria Mul-T-Mount heaters
(2 Stage wiring shown)
This is NOT a wiring schematic
L2
REV. LEVEL: 17
ECO 1-7383
11
CIRCUIT #1
LAMP NO. 1
LAMP NO. 2
CIRCUIT #2
OIPM P/N 8329
L2
L2

Advertisement