Page 1
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com A DIVISION OF OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES REFER TO COMPLETE INDEX OF IMPORTANT SAFETY INFORMATION INSIDE INFORMATION ON • Serious injury or death possible PAGE 2 •...
Page 2
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com A DIVISION OF OCH-series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING RESIDENCES REFER TO COMPLETE INDEX OF IMPORTANT SAFETY INFORMATION INSIDE INFORMATION ON • Serious injury or death possible PAGE 2 •...
SPECIFICATIONS DESCRIPTION Fostoria multi-purpose OCH series electric infrared heaters are designed to provide efficient spot heating for many commercial and industrial applications. All EXPLOSION HAZARD models operate with a single quartz tube emitter FIRE HAZARD • Serious injury or death...
Each heater is equipped with two black hi-temperature silicone lead wires and one green lead wire for ground termination. Make sure power source conforms to the heater requirements. Use only Fostoria quartz tubes. ELECTRICAL SHOCK 1. Insert quartz tube in the “L”-shaped slots in heater housing. HAZARD 2.
Page 6
HEATER INSTALLATION continued Adjustable mounting brackets SUSPENSION ALTERNATIVES Your OCH series heater can be mounted with either adjustable mounting brackets or chain suspension. Both options are included with your heater. Standard Mounting: In the hardware bag shipped with your heater you will find two adjustable mounting brackets and fastening hardware.
• Disconnect from electrical supply before installing or See page 7 for optional electrical box kits available servicing this heater. from Fostoria Industries. • This appliance must be TOTALLY EXPOSED OUTDOOR APPLICATIONS connected to a properly bonded (grounded) For totally exposed outdoor applications (not ceiling electrical source.
Page 8
WIRING INSTRUCTIONS continued OPTIONAL ELECTRICAL BOX ASSEMBLY Model No. Part No. Voltage Plug Configuration OCH-EBK-120 08715502 120V NEMA 5-15P OCH-EBK-208 08715602 208V OCH-EBK-240 08715702 240V NEMA 6-20P OCH-EBK-480 08715802 277 & 480V OCH-EBK kits consist of: (1) Electrical box assembly (2) Wire Nuts -120V &...
WIRING INSTRUCTIONS continued STEP #3 Wiring 1. Factory installed black lead: a. Route the lead wire thru the chase nipple into the electrical box assembly. b. Trim lead wire to approx 6 inches in length and strip end approx 1/2 inch. c.
LIMITED WARRANTY FOSTORIA INDUSTRIES, INC. – 1200 North Main Street - Fostoria, Ohio 44830 - (419) 435-9201 The warranty herein set forth is in lieu of all other warranties expressed or The obligation of Fostoria Industries, Inc. under the terms of this warranty, shall be to implied.
Page 11
INDEX Index Page 2 Safety Signal Word Definitions Page 2 Specifications Page 3 Quartz Tube Installation Page 4 Heater Installation Pages 4 & 5 Wiring Page 6 Replacement Parts Page 7 Maintenance Page 8 Troubleshooting Page 8 Warranty Page 8 ATTENTION: The table to the right provides definitions of the signal words that...
SPECIFICATIONS DESCRIPTION Fostoria multi-purpose OCH-SS series electric infrared heaters are designed to provide efficient spot heating many commercial industrial EXPLOSION HAZARD applications. All models operate with a single quartz FIRE HAZARD • Serious injury or death tube emitter included with the heater, are easily installed, and are equipped with spectral reflectors for may occur.
Each heater is equipped with two black hi-temperature silicone lead wires and one green lead wire for ground termination. Make sure power source conforms to the heater requirements. Use only Fostoria quartz tubes. ELECTRICAL SHOCK Insert quartz tube in the “L”-shaped slots in heater housing.
Page 14
HEATER INSTALLATION continued Adjustable mounting brackets SUSPENSION ALTERNATIVES Your OCH-SS series heater can be mounted with either adjustable mounting brackets or chain suspension. Both options are included with your heater. Standard Mounting: In the hardware bag shipped with your heater you will find two adjustable mounting brackets and fastening hardware.
Page 15
WIRING CONDUIT Required conduit size: ½” ELECTRICAL SHOCK HAZARD All conduit fittings and conduit are supplied by the customer. • Serious injury or death may occur. TOTALLY EXPOSED OUTDOOR APPLICATIONS • Disconnect from electrical For totally exposed outdoor applications (not ceiling supply before installing or protected) all conduit and fittings must be NEMA servicing this heater.
REPLACEMENT PARTS LIST OCH-46 OCH-57 ITEM QTY VOLTAGE DESCRIPTION PART NO. PART NO. 8561801 8560401 REFLECTOR 8561201 REFLECTOR END CAP 2326500 SCREW 8-32 X 3/8 04432302 04418102 04416602 04418002 04414702 QUARTZ TUBE 04419302 04419402 04419502 8561039 ADJUSTABLE MOUNTING BRACKETS 2402739 SCREW 10-32 X ½...
LIMITED WARRANTY FOSTORIA INDUSTRIES, INC. – 1200 North Main Street - Fostoria, Ohio 44830 - (419) 435-9201 The warranty herein set forth is in lieu of all other warranties expressed or The obligation of Fostoria Industries, Inc. under the terms of this warranty, shall be to implied.
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 www.fostoriaindustries.com A DIVISION OF CH Series COMFORT HEATERS INDOOR* and Semi-Protected** OUTDOOR USE *EXCLUDING RESIDENCES **COVERED APPLICATIONS REFER TO COMPLETE INDEX OF IMPORTANT SAFETY INFORMATION ON INFORMATION INSIDE PAGE 2 •...
Page 19
INDEX Index Page 2 Safety Signal Word Definitions Page 2 Specifications Page 3 Quartz Tube Installation Page 4 Heater Installation Pages 4 & 5 Wiring Page 6 Replacement Parts Page 7 Maintenance Page 8 Troubleshooting Page 8 Warranty Page 8 ATTENTION: The table to the right provides definitions of the signal words that...
SPECIFICATIONS DESCRIPTION Fostoria multi-purpose CH series electric infrared EXPLOSION HAZARD heaters are designed to provide efficient spot heating FIRE HAZARD for many commercial and industrial applications. All • Serious injury or death models operate with a single quartz tube emitter may occur.
QUARTZ TUBE INSTALLATION Each heater is equipped with two hi-temperature silicone lead wires and a ground termination. Make sure power source conforms to the heater requirements. Use only Fostoria quartz tubes. ELECTRICAL SHOCK 1. Insert quartz tube in the “L”-shaped slots in heater housing.
Page 22
HEATER INSTALLATION continued SUSPENSION ALTERNATIVES STANDARD MOUNTING Your CH series heater can be mounted with either the standard chain suspension or optional CH-MB(p/n- 04863802), adjustable mounting bracket kit. Standard Mounting: The heater is to be chain-hung as shown in figure 1. Cut the 16ga.
Page 23
WIRING INTERNAL WIRING DIAGRAM CH heaters are equipped with two Hi-temperature ELECTRICAL SHOCK silicone lead wires bonding* (ground) HAZARD termination. • Serious injury or death may occur. • Disconnect from electrical Heater Housing supply before installing or servicing this heater. •...
Page 24
REPLACEMENT PARTS LIST CH-46C CH-57C ITEM QTY DESCRIPTION PART NO. PART NO. 8561801 8560401 REFLECTOR 8561201 REFLECTOR END CAP 2326500 SCREW 8-32 X 3/8 04432302 04414702 QUARTZ TUBE 3440300 CHAIN KIT Page 7 of 8 Issue Date: 08-27-07 Rev. Date: 04-24-08 Rev.
Page 25
LIMITED WARRANTY FOSTORIA INDUSTRIES, INC. – 1200 North Main Street - Fostoria, Ohio 44830 - (419) 435-9201 The warranty herein set forth is in lieu of all other warranties expressed or The obligation of Fostoria Industries, Inc. under the terms of this warranty, shall be to implied.
Need help?
Do you have a question about the OCH-SS series and is the answer not in the manual?
Questions and answers