3.4
Safety devices
This product has a motor protection system. It monitors current consumption and motor temperature and
prevents the product from overheating.
If the motor is overloaded through application of excessive working pressure, the product's performance
drops noticeably or it might stall completely.
If the power tool stalls or slows significantly due to overloading, release the pressure applied to the product
and then allow it to run under no load for approx. 30 seconds.
4
Consumables
The following accessory tools can be used with the cut-out tool:
Drywall
Guidepoint bit (3.2 mm (1/8"))
Standard bit (3.2 mm (1/8"))
Universal guidepoint bit (4 mm (5/32"))
Window/door guidepoint bit (6.4 mm (1/4"))
Metal
Metal bit (4 mm (5/32"))
5
Technical data
5.1
Cut-out tool
Rated voltage
Rated speed under no load
Weight in accordance with EPTA procedure 01
Weight B 22/2.6
Weight B 22/3.0
Weight B 22/5.2
Operating temperature
Storage temperature
Clamping nut
Collet diameter
Cutting bit shank diameter
5.2
Battery temperature ranges
Battery operating temperature
Battery charging starting temperature
Battery storage temperature
5.3
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
16
English
SCO 6-A22
21.6 V
30,000 /min
1.4 kg
0.48 kg
0.58 kg
0.78 kg
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
16 mm (5/8") external
hexagon
3.2 mm (1/8"), 4 mm
(5/32"), 6.4 mm (1/4")
3.2 mm (1/8"), 4 mm
(5/32"), 6.4 mm (1/4")
−17 ℃ ... 60 ℃
−10 ℃ ... 45 ℃
−20 ℃ ... 40 ℃
2194405