Summary of Contents for Baumuller DA 100
Page 1
Commissioning and Maintenance TAM 00612 DA 100 – 280 W Three-phase asynchronous motor Water-cooled Version: 06 / 2011 TAM 00612 English DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Page 2
No liability can be accepted concerning the correctness of this documentation unless otherwise specified in the General Conditions of Sale and Delivery. BAUMÜLLER NÜRNBERG GmbH Motors division 90482 Nürnberg, Germany www.baumueller.com TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Failure to observe can lead to serious injury Warning about a hot surface Electrostatically sensitive components Failure to observe can lead to damage to the system or peripheral equipment. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
If, in special cases (for utilization in non-industrial applications), more stringent requirements are in place, e.g., protection against contact with a child's fingers, these conditions must be met by the customer when installing the system. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Baumüller head office in Nuremberg should be notified immediately. In both of the above cases, commissioning must not take place until the error has been rectified by a specialist. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
The nameplate is used to identify each electric motor. The unique motor number is clearly shown on each nameplate and is essential for internal tracking procedures. It must be possible to read the nameplate at all times. Never remove the nameplate from your motor. Nameplate data Motor DA 100 – 132: 1 → Motor number 2 →...
Page 8
16 → Rated current I 17 → Power factor cos φ 18 → 2D code 19 → Balance quality Customer order number (optional) 20 → TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Option: Sincos encoder Option: EnDat encoder For further technical data, refer to our DA 100 - 280 technical product list online at: www.baumueller.com under Download and Technical documentation. If necessary, you can request the corresponding documentation. Caution! If the electric motor supplied is not a standard type as per the technical documentation or if special contractual arrangements have been made, there may technical differences to these Commissioning and Maintenance Instructions.
G1/2“ IG G1/4“ IG G1/4“ IG G1/4“ IG G3/8“ IG Direction of flow as req. as req. as req. as req. as req. as req. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
On shaft versions with a key, it must be ensured that the output elements rest on the shaft shoulder. Note: The chamfer or radius on the output element and the shaft radius on the shoulder must be matched. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
When coupling and uncoupling the coolant pipes, make sure that coolant does not enter the motor's terminal box. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
(minimum test pressure 1 bar). The coolant used does not have to be brought to operating temperature for this purpose. Pressure must be maintained until all areas have been tested for leaks (minimum test duration 10 minutes). TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
It is imperative that there must be no protruding wire ends. • The cable boots used match the dimensions and cross-sections of the terminals and wires. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Danger of burns! Never touch the motor housing when the motor is running at rated load. The surface temperatures on the motors may exceed 70 °C. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled...
• Check the motor surface and connection cables for dirt, e.g. layers of dust, oil deposits, dampness and leaks etc. • Check the maintenance intervals. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Coupling element or driven Rebalance machine poorly balanced Inadequate alignment of the drive Realign machine set train Check and tighten screwed Fixing screws loose connections TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
(see Section 5.2). If an optional shaft sealing ring is used, it must be checked at regular intervals to ensure it is functioning correctly (leakage). TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
The motor must be disposed of in accordance with the relevant national and local regulations within the framework of the normal recycling process. The encoder electronics (if provided) must be disposed of in the proper manner as electronic scrap. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
* Terminal box screen laid on terminal in the terminal box. List: Terminal box versions Other cable entries and terminals are available on enquiry only. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
(encoder with Hiperface-port from SICK / Stegmann companies) Signal ref cos + 485 ref sin View of contact side - 485 of the female connector TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Control port: ECN1313 / EQN 1325 / EQN 425 (encoder with EnDat 2.1-port from Heidenhain companies) Signal View of contact side Clock of the female connector Clock inv. (Inner screen) Data Data inv. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
• The encoder from Section 7.3 to 7.5 are components susceptible to ESD. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled...
Pressure drop 2,55±10 0,29±10% 0,33±10% 1,05±10% 1,35±10% 2,55±10% in bar Temperature rise in K (10) (10) (12) (13) (13) (max.) Max. coolant pressure in bar TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Page 25
The latest version of the General Terms and Conditions of Sale of Baumüller Nürnberg GmbH always apply. These will be made available to you at the latest on conclusion of the contract. TAM 00612 DA 100 – 280 W 06 / 2011 Three-phase synchronous motor water-cooled English...
Need help?