Summary of Contents for Baumuller DSM1

  • Page 1 Commissioning and Maintenance Instructions TAM00720_eng DSM1 Three-phase-synchronous motor TAM00720 DSM1 10/2015 Version: 10/2015 Three-phase-synchronous motor English English...
  • Page 2 Baumüller products. No responsibility is assumed for the correctness of this documentation unless noted otherwise in the terms and conditions of sale and delivery. BAUMÜLLER DirectMotion GmbH D-37581 Bad Gandersheim www.baumueller.de TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 3: Table Of Contents

    7.1 Resolver – KTY within the power connection ................21 7.2 Resolver – KTY within the signal connection ................22 7.3 SRS/SRM50; SKS/SKM36 – KTY within the power connection ..........24 7.4 SRS/SRM50; SKS/SKM36 – KTY within the signal connection: ..........25 TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 4: General Safety Instructions

    Warning of hot surfaces The symbol indicates that, if not avoided, could result in severe injuries. Electrostatic sensitive devices The symbol indicates that the installation or work environment could be damaged, if not avoided. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 5: Intended Use

    If higher requirements are demanded in special cases as e.g. in use within non- industrial systems, these requirements must be ensured during installation (e.g. touch protection against children’s fingers). Motor version with rare-earth magnets: TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 6: Prohibition Of Unauthorized Modifications And Changes

    Any unauthorized modifications and alterations at the electric motor are prohibited due to safety reasons. Contact the motor manufacturer in case of need. Generally, never dismount or decommission safety devices to operate the electric mo- tor. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 7: Operating Conditions

    If visible deficiencies or incomplete delivery are determined the responsible Baumüller subsidiary or the main Baumüller company in Nuremberg must be informed. In both cases motor commissioning is prohibited until the deficiency was professionally corrected. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 8: Technical Data

    Protection class (EN 60034-5) considering the shaft sealing IP 44 Standard: without shaft sealing ring IP 65 Optional: with shaft sealing ring, without considering the shaft sealing IP 65 Standard: without shaft sealing ring TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 9 If the delivered electric motor doesn’t correspond to the standard version accordant to the technical list or if special contractual terms were agreed upon, technical deviations referring to this commissioning and maintenance guide can occur. Please, ask for the corresponding technical additions. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 10: Transport, Temporary Storage

    However, if a longer storage cannot be avoided, then the environmental conditions (class 1K2/1M1) mentioned in DIN EN 60721-3-1 must be observed. Contrary to the DIN the temperature range may be exceeded from – 15 °C to + 60 °C. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 11: Installation Conditions, Cooling Specifications

    500 x 500 x 10 0,25 DSM190 500 x 500 x 10 0,25 Chart 1: Installation surface The heat dissipation conditions improve where the installation surfaces are larger. An isolated installation of the motors is not permitted! TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 12: Balancing, Output Elements, Vibrations

    2 must not be exceeded: Thread Tightening torque in Nm Chart 2: Tightening torques demonstrated with a locking bolt S of a belt pulley Appropriate measures must be made regarding screw locking! TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 13: Installation

    (see chapter 2.6) The motor installation must allow the sufficient dissipation of heat via the housing surface and via the motor flange surface (see chapter 2.6). TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 14: Electrical Connection

    Never touch the contacts of encoders and temperature sensors with your hands or with tools, which are electrostatically charged or could be electrostatically charged! Encoders and temperature sensors are electrostatically sensitive devices. Electrical installation: TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 15 Note! In order to guarantee the protection class the turnable sockets shouldn’t be changed in their connection direction by turning them more than 5 times, as well. • Plug connections must not be exposed to any mechanical loads. If required, add anti-rotation, strain, thrust as well as flex reliefs. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 16: Commissioning, Operation

    Otherwise, the rotating rotor causes a hazard. Danger of burning! Never touch the motor housing within rated load operation. Sur- face temperatures of 70°C and above can occur at the motors. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 17: Tests Prior To Commissioning

    If streaking and scratching noises, dragging noises or the like occur, immediately put the drive out of operation and detect the cause. • Motor surface and connecting cables must be checked on dirt (e.g. dust deposits, oil contamina- tion, moisture etc.). • Maintenance intervals must be observed. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 18: Failures

    Nonconform alignment of Realign the machine unit driveline Fastening screws are loose Check and fasten the screwed fastenings Failure Cause of error Correction Running noises Foreign particles in the motor Motor manufacturer must TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 19: Inspection And Maintenance

    The current wear degree must be checked regularly. The brake must be replaced if the permissible wear limits were reached (see section 5.2). If a shaft sealing was installed optionally the correct functioning must be checked (leakage) regularly. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 20: Maintenance

    The motor must be disposed of within the normal recycling process according to the national and local rules. The encoder electronics must be correctly disposed of as electronic scrap (if an absolute encoder has been installed). TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 21: Pole Assignments (Power And Signal Connections)

    SIN - 12-pole SIN + Resolver pin contacts COS + 10 P REF + REF - Housing s.c. s.c.: Shielding connection (1) Brake optional, see rating plate Schematic representation: with view to the connection TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 22: Resolver - Kty Within The Signal Connection

    COS + REF + 10 P REF - KTY - Temp. sensor KTY + Housing s.c. s.c.: Shielding connection (1) Brake optional, see rating plate Schematic representation: with view on the connection TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 23 Signal REF - KTY - Temp. 12-pole sensor KTY + pin contacts n.c. n.c. n.c. n.c. Housing s.c. s.c.: Shielding connection (1) Brake optional, see rating plate Schematic representation: With view on the connection TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 24: Srs/Srm50; Sks/Skm36 - Kty Within The Power Connection

    REFCOS Data + 12-pole + SIN pin contacts REFSIN Hiperface Data - 10 P + COS Housing s.c. s.c.: Shielding connection (1) Brake optional, see rating plate Schematic representation: With view on the connection TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 25: Srs/Srm50; Sks/Skm36 - Kty Within The Signal Connection

    • Encoders can be ESD components. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...
  • Page 26 As a general rule the latest version of the „General Terms of Sale and Delivery“ of Baumüller DirectMo- tion GmbH is valid. The „General Terms of Sale and Delivery“ have been at your disposal since contract conclusion at the latest. TAM00720 DSM1 10/2015 Three-phase-synchronous motor English...