Summary of Contents for Baumuller DA 100

  • Page 1 Commissioning and Main- tenance Instructions TAM 00609 DA 100 – 280 DA 100 Three-phase asynchronous Drehstro motor luftgeküh Air-cooled TAM 00609 Version: Version: 03/2015 DA 100 – 280 03 / 2015 English deutsch Three phase asynchronous motor air cooled Englisch...
  • Page 2 No liability can be accepted concerning the correctness of the product information unless otherwise specified in the General Conditions of Sale and Delivery. BAUMÜLLER NÜRNBERG GmbH Motor Division D-90482 Nuremberg www.baumueller.de TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 3: Table Of Contents

    Sincos-encoder ECN1313 / EQN 1325 / EQN 425 (Heidenhain) EnDat 2.1– Pin assignment ..22 Encoder ECN1325 / EQN 1337 (Heidenhain) Endat 2.2 – Pin assignment (M23) ......23 7.2.4 Fan connection / terminal designation ....................24 TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 4: General Safety Instructions

    Non-observance can lead to serious injury. Warning concerning hot surface Non-observance can lead to serious injury. Electrostatically sensitive components Non-observance can cause damage to the plant or the environment. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 5: Designated Use

    If, in special cases, greater requirements are placed – for utilization in non-industrial applica- tions – (such as protection against contact with a child’s fingers), these conditions must be by the customer met when installing the system. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 6: Prohibition Of Unauthorized Modifications And Changes

    Baumüller office or the Baumüller head office in Nuremberg should be notified immediately. In both of the above cases, commisioning may not be made until the error has been fixed correctly. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 7: Type Plate

    It must be possible to read the type plate at all times. Never remove the type plate from your motor. Type plate data of the DA 100 – 132 motor: 1 →...
  • Page 8 14 → Rated current I 15 → Power factor cos φ 16 → 2D-Code 17 → Vibration class 18 → (optional) part number of customer TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 9: Technical Data

    Installation altitude (EN 60034-1) -30 °C…+60 °C (+ 85 °C, refer to chapter 2.5) Storage Bearing Roller bearing with permanent lubrication (DA 100 - 225) or with a relubricating device (DA 280) (refer to chapter 5.2) Computed operational life 20.000 h (approximate value) Amplitude of vibration (EN 60034-14) Level A (formerly N);...
  • Page 10: Transport, Intermediate Storage

    2-pin resolver Option: Sincos encoder For further technical values, please refer to our technical product list DA 100 - 280 on the website in the download area – technical documents. Please, contact us for the ac- www.baumueller.de cordant documents, if required.
  • Page 11: Installation Conditions, Cooling Details

    In the case of shafts with a featherkey, make sure that the output elements are fitting the shoulder of the shaft. Note: The chamfer or radius at the output element and the shaft radius at the shoulder have to be harmonized. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 12: Mounting

    They must be precisely aligned with the connecting shafts to prevent the bearing, shafts and housing being exposed to damaging loads through TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled...
  • Page 13: Electrical Connection

    To enhance operational safety, we recommend that the ready-made connection cables of Baumüller are used. • Prior to connection, the female connectors, connectors and terminal box must be checked for damage, corrosion, dirt and dampness. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 14 Note: All lead-ins that are not used must be closed off with the sealing caps. The sealing ele- ments must be fully functional and undamaged when closing the terminal box. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled...
  • Page 15: Commissioning, Operation

    Otherwise, danger due to a rotating rotor. Danger of burns! Never touch the motor housing when motor is running at rated load. Sur- face temperatures can rise up to 70°C. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 16: Tests Prior To Commissioning

    Check the motor surface and connection cables for dirt, such as layers of dust, oil deposits, dampness and leaks etc. • Check air inlet and outlet openings and any interposed filters for dirt accumulation • Check the maintenance intervals. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 17: Malfunctions

    Drive overloaded Check motor load and compare Motor temperature monitoring with type plate unit responds Brake does not release fully - Repair by motor manufacturer TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 18: Inspection And Maintenance

    The brake must be replaced on reaching the permitted abrasion limit (refer to Sec- tion 5.2) If equipped with the optional shaft sealing ring, this must be checked regularly to ensure that it is functioning correctly (leaks).. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 19: Maintenance

    The motor must be disposed in compliance with the national and local regulations within the framework of the normal recycling process. The encoder electronics (if applicable) must be disposed correctly as electronic scrap. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 20: Main Connection / Terminal Block Designation

    3 x M16 * terminal box screening led into terminal in terminal box. Combination: Terminal box designs Other cable glands and terminals on request, only. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 21: Encoder Connection

    7.2.2 Sincos-encoder SRS/SRM50 (Fa. SICK / Stegmann) – Pin assignment Signal ref cos + 485 ref sin - 485 View to the contact side of the fe- male connector TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 22: Sincos-Encoder Ecn1313 / Eqn 1325 / Eqn 425 (Heidenhain) Endat 2.1- Pin Assignment

    7.2.3 Sincos-encoder ECN1313 / EQN 1325 / EQN 425 (Heidenhain) EnDat 2.1– Pin assignment Signal Clock View to the contact side of the female connector Clock inv. (Inner shield) Data Data inv. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 23: Encoder Ecn1325 / Eqn 1337 (Heidenhain) Endat 2.2 - Pin Assignment (M23)

    The pin assignment of other encoder types with optional cables of the thermal sensor via the encoder cable can be taken from the enclosed circuit diagrams or from the technical documents. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 24: Fan Connection / Terminal Designation

    460-600 V 60 Hz 420-480 V 60 Hz 0,62 1,05 3,65 345-460 V 50 Hz 345-480 V 60 Hz 10,5 The rated current values are maximum values TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...
  • Page 25 The latest version of “The General Terms and Conditions of Sale” drawn up by Baumüller Nürnberg GmbH always apply. These are provided on the conclusion of the contract, at the latest. TAM 00609 DA 100 – 280 03 / 2015 Three phase asynchronous motor air cooled Englisch...