TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
WB
MBH
CFM
°F
72
64
67
57
2000
62
54
57
54
72
62
67
55
1800
62
52
57
52
72
59
67
54
1600
62
50
57
50
72
58
67
52
1400
62
49
57
49
72
57
67
50
1200
62
48
57
48
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
.1
CAP
WB
MBH
CFM
°F
72
56
67
50
2000
62
47
57
47
72
54
67
49
1800
62
46
57
46
72
53
67
48
1600
62
44
57
44
72
51
67
46
1400
62
43
57
43
72
50
67
44
1200
62
42
57
42
1.
These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from Table 9 or 11, multiply
this value by 3.425 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2.
These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan
motor power input is 0.36kW. Refer to Tables 9 or 11 for the kW of the supply air blower motor.
NOMINAL RATING
Unitary Products Group
TEMPERATURE OF AIR ON CONDENSER COIL
85°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
INPUT
kW
86
83
80
77
3.9
45
39
33
27
3.8
55
49
43
37
3.8
54
54
53
47
3.8
54
54
54
48
3.9
42
36
31
25
3.8
51
46
40
35
3.8
52
52
49
44
3.8
52
52
51
45
3.9
38
33
29
24
3.8
48
43
38
33
3.7
50
50
46
41
3.7
50
50
47
42
3.8
35
31
27
23
3.8
44
39
35
31
3.7
48
47
43
39
3.7
49
48
44
40
3.8
32
29
25
21
3.8
40
36
32
29
3.7
47
44
40
36
3.7
48
45
41
37
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
INPUT
kW.
86
83
80
77
4.7
42
36
30
25
4.6
50
45
39
33
4.5
47
47
47
41
4.5
47
47
47
44
4.7
39
34
29
23
4.6
47
43
37
32
4.5
46
46
45
40
4.5
46
46
46
42
4.7
36
31
27
22
4.6
45
40
35
31
4.6
44
44
43
38
4.5
44
44
44
39
4.7
33
29
25
21
4.6
41
37
33
28
4.5
43
42
40
36
4.5
43
43
41
37
4.7
30
27
23
19
4.6
37
33
30
26
4.5
42
41
37
33
4.5
42
41
38
34
1
, MBH
TOTAL
POWER
.1
CAP
INPUT
MBH
kW.
74
71
68
21
-
-
60
31
25
19
53
41
35
29
50
42
36
30
50
20
-
-
58
30
24
19
52
39
33
28
49
40
35
29
49
19
-
-
57
29
24
19
52
36
32
27
47
38
33
28
47
18
-
-
55
27
22
18
49
34
30
26
46
36
31
27
46
17
-
-
53
25
21
17
47
33
29
25
45
34
30
26
45
1
, MBH
TOTAL
POWER
.1
CAP
INPUT
MBH
kW.
74
71
68
19
-
-
53
28
22
16
47
35
29
23
44
38
32
26
44
17
-
-
51
27
21
16
46
34
29
23
43
36
31
26
43
17
-
-
49
26
21
16
44
33
29
24
41
34
30
25
41
16
-
-
48
24
20
16
43
31
27
23
40
32
28
24
40
16
-
-
47
22
19
15
42
29
26
22
39
30
27
23
39
ALL SENSIBLE CAPACITY
95°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
4.2
44
38
32
26
4.1
53
47
41
35
4.0
50
50
50
44
4.0
50
50
50
46
4.2
41
35
30
24
4.1
50
44
39
34
4.1
49
49
47
42
4.1
49
49
49
44
4.2
38
33
28
23
4.2
47
42
37
32
4.1
47
47
45
40
4.1
47
47
46
41
4.2
34
30
26
22
4.2
42
38
34
30
4.1
46
45
42
37
4.1
46
46
43
38
4.2
31
28
24
20
4.2
38
35
31
27
4.1
45
42
38
34
4.1
45
43
39
35
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
5.2
41
35
29
23
5.1
47
44
38
32
5.0
44
44
44
38
5.0
44
44
44
42
5.1
38
33
27
22
5.1
45
41
36
31
5.0
43
43
43
37
5.0
43
43
43
40
5.1
35
30
25
21
5.1
43
39
34
29
5.0
41
41
41
36
5.0
41
41
41
37
5.1
32
28
24
20
5.0
40
35
31
27
5.0
40
40
38
34
5.0
40
40
39
35
5.1
30
26
22
18
5.0
36
32
29
25
5.0
39
39
35
32
5.0
39
39
36
33
1
, MBH
74
71
68
20
-
-
29
23
17
38
32
26
40
34
28
19
-
-
28
23
18
37
31
26
38
33
27
18
-
-
28
23
18
35
31
26
37
32
27
17
-
-
26
21
17
33
29
25
34
30
26
16
-
-
23
20
16
31
27
23
32
28
24
1
, MBH
74
71
68
17
-
-
26
20
14
32
26
20
36
30
24
17
-
-
25
20
14
32
26
21
34
29
24
16
-
-
24
19
15
31
26
22
32
28
23
15
-
-
23
19
14
30
25
21
31
26
22
15
-
-
21
18
14
28
24
21
29
25
22
9