York FRCS024 Technical Manual page 9

Split-system air conditioners 14 seer 2 thru 5 nominal tons

Advertisement

COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handler
Coil
N1AHB1206
G2FD036S17
N1VSB12
G2FD036S17
N1VSB12
G2FD046S17
F2FP045
F2RP/F2FP036
G1UA036S14
G1UA036S17,21
G1FA036S17,21
G2FD030S17
G1UA048S21,24
G2FD036S17
G2FD036S21
G2FD048S21,24
G1HD048S
G1NA036S17L
G1NA042S24W
G1NA048S21D
G1UA036S14
MDD48DSD
Unitary Products Group
FRCS0301BD
G1FA048S21, 24
ID CFM
800
ID DB
85
80
75
ID WB
72
67
62
T.C.
35.9
32.8
30.2
S.C.
21.2
21.2
20.4
K.W
1.68
1.70
1.71
T.C.
34.1
31.1
28.6
S.C.
20.6
20.6
19.7
K.W
1.89
1.89
1.89
T.C.
32.3
29.5
27.1
S.C.
20.0
20.0
19.2
K.W
2.07
2.05
2.03
T.C.
30.5
27.8
25.6
S.C.
19.4
19.4
18.6
K.W
2.23
2.19
2.16
T.C.
28.6
26.0
24.0
S.C.
18.8
18.7
17.9
K.W
2.37
2.32
2.27
T.C.
26.7
24.2
22.3
S.C.
18.2
18.0
17.2
K.W
2.51
2.45
2.38
T.C.
S.C.
KW
0.96
0.95
1.01
0.98
0.95
0.94
1.00
0.99
0.91
1.02
0.99
1.00
0.99
0.99
0.99
0.95
0.92
1.00
0.95
0.92
1.01
0.95
0.92
1.01
0.95
0.94
1.01
1.00
1.00
1.00
0.96
0.95
1.01
0.96
0.96
0.98
1.01
1.01
1.00
1.00
0.99
1.00
0.97
0.92
1.00
0.97
0.95
1.00
0.97
0.92
1.00
0.95
0.92
1.00
0.97
0.92
1.00
1000
70
85
80
75
57
72
67
62
27.0
36.6
33.5
30.9
21.4
22.8
22.9
22.0
1.70
1.68
1.69
1.70
25.6
34.7
31.7
29.3
20.8
22.2
22.2
21.4
1.86
1.89
1.89
1.89
24.2
32.8
30.0
27.7
20.1
21.6
21.6
20.8
1.99
2.07
2.06
2.04
22.7
30.9
28.3
26.1
19.4
21.0
21.0
20.1
2.10
2.23
2.20
2.17
21.2
29.0
26.5
24.4
18.7
20.4
20.4
19.4
2.20
2.38
2.33
2.28
19.7
27.1
24.7
22.6
18.0
19.8
19.8
18.8
2.30
2.53
2.46
2.39
Variable Speed
Coil
Furnace
G8V***12UHA
G1FA036S14
G8V***12UHA
G1UA036S14
G8V***16UHB
G2FD036S17
G9V***12DHB
G2FD036S17
G9V***12UPB
G2FD036S17
036-21004-002 Rev. B (0602)
1200
70
85
80
75
57
72
67
62
27.7
36.9
33.8
31.4
23.1
23.9
23.9
23.1
1.70
1.67
1.69
1.70
26.2
35.0
32.0
29.6
22.4
23.3
23.3
22.4
1.87
1.89
1.89
1.89
24.8
33.1
30.4
28.0
21.7
22.7
22.7
21.7
2.00
2.07
2.06
2.05
23.4
31.1
28.6
26.3
21.1
22.1
22.1
21.1
2.12
2.24
2.21
2.18
22.1
29.3
26.8
24.7
20.3
21.5
21.4
20.5
2.23
2.38
2.34
2.29
20.8
27.5
25.0
23.0
19.5
20.9
20.7
19.9
2.34
2.52
2.47
2.40
T.C.
S.C.
0.96
0.92
0.96
0.92
1.00
0.95
1.01
0.95
0.97
0.95
70
57
28.1
24.2
1.70
26.6
23.6
1.87
25.2
22.8
2.01
23.9
22.0
2.13
22.5
20.8
2.24
21.1
19.6
2.35
KW
0.95
0.95
0.93
1.00
0.95
9