Download Print this page
York FRCS024 Technical Manual
York FRCS024 Technical Manual

York FRCS024 Technical Manual

Split-system air conditioners 14 seer 2 thru 5 nominal tons

Advertisement

Quick Links

TECHNICAL
TECHNICAL
GUIDE
GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
14 SEER
MODELS:
FRCS024 THRU 060
(2 THRU 5 NOMINAL TONS)
R
P
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ari.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 14 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of copper tube and aluminum fins.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and desert sand matted-textured
finish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the con-
denser fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
036-21004-002 Rev. B (0602)

Advertisement

loading

Summary of Contents for York FRCS024

  • Page 1 SYSTEM IS LISTED WITH ARI. Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ari.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21004-002 Rev.
  • Page 2: Physical And Electrical Data

    036-21004-002 Rev. B (0602) Physical and Electrical Data MODEL FRCS0241BD Unit Supply Voltage Normal Voltage Range Minimum Circuit Ampacity Max Overcurrent Device Amps Compressor Type Rated Load Compressor Amps Locked Rotor Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches Rated HP Fan Motor Nominal RPM...
  • Page 3 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL ELECTRIC MODEL FRCS0241BD N1AHB0806 FRCS0301BD N1AHB1206 5,8,10,15,19 N1AHB1206 5,8,10,15,19 N1AHB1206 5,8,10,15,19 FRCS0361CD N1AHD1406 N1AHD1406 N1AHC1606 5,8,10,15,20 FRCS0421CE N1AHC1606 5,8,10,15,20 N1AHD1406 N1AHD2006 8,10,15,20,25,30 FRCS0481CE N1AHD2006 8,10,15,20,25,30 N1AHD2006 8,10,15,20,25,30 FRCS0601BF N1AHD2006 8,10,15,20,25,30 N1VSB12 FRCS0241BD...
  • Page 4 036-21004-002 Rev. B (0602) COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) 17,21 FRCS0241BD 17,21 17,21 21,24 FRCS0301BD 1125 17,21 21,24 21,24 21,24 1050 21,24 FRCS0361CD 1350 21,24 21,24 21,24 1225 21,24 FRCS0421CE 1575 21,24...
  • Page 5 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) 21,24 1650 FRCS0601BF 2150 21,24 TXV = Use 1TV700 Series Kit. Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. Refer to Quick Selection Chart for specific furnace match-up.
  • Page 6: Cooling Performance

    036-21004-002 Rev. B (0602) COOLING PERFORMANCE AIR TEMP ON CONDENSER SUCT. T/P @ COMPR. MODEL 75×F TEMP. PSIG MBH KW MBH KW MBH KW 61.5 22.9 1.42 19.4 1.63 15.9 1.82 68.5 25.3 1.45 21.6 1.67 18.0 1.90 FRCS0241BD 76.0 28.0 1.47 24.0 1.72 20.1 1.97 84.0 30.7 1.49 26.5 1.76 22.3 2.04...
  • Page 7: Typical Installation

    TYPICAL INSTALLATION 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. TYPICAL FIELD WIRING ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 CONTACTOR TERMINALS GND. COIL CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
  • Page 8 036-21004-002 Rev. B (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 9 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 10 036-21004-002 Rev. B (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 11 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 12 036-21004-002 Rev. B (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 13 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB TEMPERATURE ID WB T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 14 036-21004-002 Rev. B (0602) MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1UA 1/2 CASED UPFLOW G1FA FULL CASED UPFLOW * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) G1HD...
  • Page 15 036-21004-002 Rev. B (0602) NOTES Unitary Products Group...
  • Page 16 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2002. All rights reserved. Unitary Product Group Supersedes: 036-21004-002 Rev. A (0502) 5005 York Drive 036-21004-002 Rev. B (0602) Norman 73069...