Download Print this page

York FRCS024 Technical Manual page 4

Split-system air conditioners 14 seer 2 thru 5 nominal tons

Advertisement

036-21004-002 Rev. B (0602)
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils
FURNACE**
UNIT MODEL
CFM RANGE
(MIN.-MAX.)
700
FRCS0241BD
900
875
FRCS0301BD
1125
1050
FRCS0361CD
1350
1225
FRCS0421CE
1575
1400
FRCS0481CE
1800
For Notes See Page 5.
4
COIL
MODEL
W
14
G1FA036S14
17,21
G1FA036S17,21
-
G1HD036
17
G1NA036S17L
21
G1NA048S21D
14
G1UA036S14
17,21
G1UA036S17,21
17
G2FD030S17
14
G2FD035S14
17
G2FD036S17
21
G2FD036S21
19
MDD48DSD
14
G1FA036S14
17,21
G1FA036S17,21
21,24
G1FA048S21,24
-
G1HD048
17
G1NA036S17L
24
G1NA042S24W
21
G1NA048S21D
14
G1UA036S14
17,21
G1UA036S17,21
21,24
G1UA048S21,24
17
G2FD030S17
17
G2FD036S17
21
G2FD036S21
21,24
G2FD048S21,24
19
MDD48DSD
21,24
G1FA048S21,24
-
G1HD048
17
G1NA036S17L
24
G1NA042S24W
21
G1NA048S21D
21,24
G1UA048S21,24
17
G2FD036S17
21
G2FD036S21
21
G2FD042S21
17
G2FD046S17
21,24
G2FD048S21,24
19
MDD48DSD
21,24
G1FA048S21,24
21,24
G1FA060S21,24
-
G1HD048
24
G1NA042S24W
21
G1NA048S21D
21,24
G1UA048S21,24
21,24
G1UA060S21,24
21
G2FD042S21
17
G2FD046S17
21,24
G2FD048S21,24
24
G2FD060S24
19
MDD48DSD
21,24
G1FA048S21,24
21,24
G1FA060S21,24
-
G1HD048
24
G1NA042S24W
21
G1NA048S21D
21,24
G1UA048S21,24
21,24
G1UA060S21,24
21,24
G2FD048S21,24
24
G2FD060S24
24
G2FD061H24
19
MDD48DSD
NET MBH
RATED
CFM
TOTAL
SENS.
800
25.0
18.0
800
24.8
17.9
800
25.0
18.1
800
24.0
16.6
800
24.0
16.6
800
25.0
18.0
800
24.8
17.9
800
24.8
17.9
800
24.8
17.9
800
25.2
18.1
800
25.2
18.1
800
24.0
16.6
1000
28.4
20.0
1000
28.4
20.0
1000
30.0
21.8
1000
30.0
21.5
1000
29.0
20.0
1000
29.0
20.7
1000
29.0
20.0
1000
28.4
20.0
1000
28.4
20.0
1000
30.0
21.8
1000
28.4
20.4
1000
28.8
20.7
1000
28.8
21.0
1000
30.2
21.8
1000
29.0
20.0
1200
35.2
25.3
1200
34.8
25.0
1200
33.0
23.4
1200
34.6
25.0
1200
33.0
23.4
1200
35.2
25.3
1200
34.0
24.5
1200
34.0
24.8
1200
34.8
25.4
1200
35.0
25.6
1200
35.2
25.7
1200
33.0
23.4
1400
39.0
28.4
1400
40.5
29.6
1400
39.0
28.4
1400
40.5
29.5
1400
39.0
27.3
1400
39.0
28.4
1400
40.5
29.6
1400
39.0
28.2
1400
39.0
28.6
1400
39.5
28.9
1400
40.5
29.6
1400
39.0
27.3
1600
45.0
32.6
1600
46.5
33.9
1600
45.0
32.4
1500
46.5
32.8
1400
44.0
29.0
1600
45.0
32.6
1600
46.5
33.9
1600
45.5
33.2
1600
46.5
33.9
1600
47.0
34.3
1400
44.0
29.0
COOLING
1
SEER + TXV
SEER + TXV
W/O TDR
+ TDR*
13.85
-
13.85
-
14.00
-
13.50
-
13.50
-
13.85
-
13.85
-
13.85
-
13.85
-
14.00
-
14.00
-
13.50
-
13.00
-
13.00
-
14.00
-
14.00
-
-
13.50
-
14.00
-
13.50
13.00
-
13.00
-
14.00
-
13.00
-
13.10
-
13.10
-
-
14.00
-
13.50
14.00
-
13.75
-
-
13.00
-
14.00
-
13.00
14.00
-
13.35
-
13.35
-
13.70
-
14.00
-
14.00
-
-
13.00
-
13.50
-
14.00
-
13.25
-
14.00
-
13.00
-
13.50
-
14.00
-
13.25
-
13.50
-
13.50
-
14.00
-
13.00
-
13.40
-
13.85
-
13.25
-
14.00
-
13.00
-
13.40
-
13.85
-
13.50
-
13.85
-
14.00
-
13.00
Unitary Products Group
EER
12.30
12.20
12.35
12.00
12.00
12.30
12.20
12.20
12.20
12.35
12.45
12.00
11.75
11.65
12.40
12.40
11.95
12.00
11.95
11.75
11.65
12.40
11.65
11.80
12.10
12.50
11.95
12.30
12.30
11.30
12.00
11.30
12.30
11.80
12.05
12.10
12.20
12.45
11.30
11.45
11.80
11.50
11.75
11.50
11.45
11.80
11.35
11.45
11.60
11.80
11.50
11.50
11.80
11.45
11.85
11.50
11.50
11.80
11.60
11.80
11.90
11.50

Advertisement

loading