Cell Voltage Monitor & Logger
4)
Alarm Trigger Settings: Select【Alarm Trigger】, press < > and the screen shows:
ALARM TRIGGER
Over Voltag
Low Voltage
Difference
Time Over
<▲> or <▼> to select items, press < > to shift select /,
press< > for 3 seconds to confirm amendment and return.
Select【Over Voltage】Cell or pack voltage are over HV setting value,
then it alarms.
Select【Low Voltage】Cell or pack voltage are lower LV setting value,
then it alarms.
Select【Difference】Cell voltage is over ▣V or the pack voltage
difference is over ▣P setting value, then it alarms.
Select【Time Over】 entering HOLD status time is over setting safety
time ,then it alarms.