ZCU-14 layout
X12
X13
X205
Description
XPOW
External power input
XAI
Analog inputs
XRO1
XAO
Analog outputs
XD2D
Drive-to-drive link
XRO2
XRO1
Relay output RO1
XRO2
Relay output RO2
XRO3
Relay output RO3
XRO3
XD24
Digital input interlock (DIIL) and +24 V output
XDIO
Digital input/outputs
XPOW
XDI
Digital inputs
J1, J2
XSTO
Safe torque off connection (inverter unit only).
Note: This connection only acts as a true
XAI
Safe torque off input when the ZCU is con-
trolling an inverter unit. When the ZCU is
controlling a supply unit, de-energizing the
inputs will stop the unit but will not constitute
a true safety function.
XAO
X12
Connection for FSO-xx safety functions
module (inverter unit only).
J3
X13
Control panel connection
XD2D
X202
Option slot 1
X203
Option slot 2
X204
Option slot 3
XSTO
X205
Memory unit connection (memory unit inser-
ted in the drawing)
J1, J2
Voltage/Current selection jumpers (J1, J2) for
analog inputs
XDI
J3
Drive-to-drive link termination switch (J3)
J6
Common digital input ground selection jumper
XDIO
(J6).
J6
XD24
Control units of the drive 43