110/113/114/115/117
Users Manual
Function
k CHEK
Ohms
Diode Test
Ohms
Diode Test
MIN MAX Recording Accuracy and Response Time (113)
Specified accuracy of the measurement function ±40 counts in k CHEK for changes >500 ms in duration, ±12 counts in e for changes
>325 ms in duration. Typical 100 ms response to 80 %. Response time not specified for capacitance.
18
Table 8. Input Characteristics (113)
Input Impedance (Nominal)
~3 kΩ <300 pF
Open Circuit Test Voltage
<2.7 V dc
<2.7 V dc
Common Mode Rejection Ratio
>60 dB at dc, 50 or 60 Hz
Full Scale Voltage
<0.7 V dc
<2.000 V dc
Short Circuit Current
<350 μA
<1.0 mA