Required corrections are contained in the following regulations or can be downloaded on the Internet. The current version is available for download on our web site http://www.iba-ag.com. Protection note Windows® is a label and registered trademark of the Microsoft Corporation. Other product and company names mentioned in this manual can be labels or registered trademarks of the corresponding owners.
ibaCom-L2B-x-8 Manual About this manual This manual describes the construction, the use and the operation of the device ibaCom-L2B-x-8. Target group This manual addresses in particular the qualified professionals who are familiar with handling electrical and electronic modules as well as communication and measurement technology.
Manual ibaCom-L2B-x-8 Used symbols If safety instructions or other notes are used in this manual, they mean: The non-observance of this safety information may result in an imminent risk of death or severe injury: By an electric shock! Due to the improper handling of software products which are coupled to input and output procedures with control function! The non-observance of this safety information may result in a potential risk of death or severe injury!
(one master for one slave only !) For each slave (each slave represents an iba module which consists of 32 analog plus 32 binary signals) the following telegram modes can be chosen: ...
128 MB RAM or better At least one free PCI slot with 5V cable (V2.2, 5 V, 32/64 bit) Please see http://www.iba-ag.com for further details on a properly outfitted workstation. Software Microsoft Windows NT4.0 (SP 6), 2000, XP, 2003, Win 7 ...
ibaCom-L2B-x-8 Manual Device Indicators, Interfaces & Connectors Device Front plate View ibaL2B-4-8 Profibus connector, 7-segment display and status LEDs Assembly side Termination resistor ibaL2B-8-8 Profibus connectors, 7-segment display and status LEDs Assembly side Termination resistor Interfaces and Indicators Found on Device Front at Top 5.1.1 Device LEDs Run, Link and Error LEDs indicate the operational state of the L2B channels.
Manual ibaCom-L2B-x-8 5.1.2 7-Segment Display The 7-segment display shows the following information: Board ID (ranging from 0...3) - after board was initialized The decimal point in the display indicates whether the board is working as interrupt master / internal (dot is on) or ...
6. If more than one iba card are used connect all iba cards with the synchronization cable. 7. Close the computer, connect the power supply and start it.
Manual ibaCom-L2B-x-8 Removing the Card In order to remove the card from the PC, please follow these steps: 1. Stop and switch off the computer, disconnect it from the power supply and open it. 2. Release the screw in the front panel. 3.
ibaCom-L2B-x-8 Manual Windows XP Driver installation The ibaCom-L2B-x-8 cards comply with the Plug & Play standard of Windows. After the card has been plugged in for the first time and after Windows has finished its startup after booting the Found New Hardware Wizard pops up for introduction to the installation of the drivers.
Page 14
The system is looking for driver software and installs it automatically. Finally click on <Finish>. If you like to check if the card was properly installed open the Windows „Device Man- ager“ and look for the card under the iba devices node. Issue 3.2...
ibaCom-L2B-x-8 Manual Configuration in ibaPDA-V6 Other documentation For a more detailed description of the board’s configuration in ibaPDA-V6 please refer to the ibaPDA-V6 manual or online help. If card has been installed correctly and the license for L2B Profibus is enabled in the dongle the card should be available in the I/O manager’s signal tree as a data inter- face.
Manual ibaCom-L2B-x-8 Diagnosis in ibaPDA-V6 The essential tools for diagnosis are integrated in the I/O manager of ibaPDA-V6. General card diagnosis The image of the card as shown in chapter 8 provides essential information. The graphical representation of the card shows the animated displays and indicators of the real card.
ibaCom-L2B-x-8 Manual Processor information Processor information is for support service and error diagnosis only. Processor information Memory view This view provides very detailed information about memory use for service purposes. It shows communication data and telegram contents. The flashing green light indicates a running system.
Manual ibaCom-L2B-x-8 Synchronizing Multiple iba PCI Devices Shut down the computer, remove the power connection and plug in the other iba PCI cards. Connect the synchronization cable between the devices. This is now necessary be- cause the PCI bus does not support any synchronization signal on the bus which is available at all slot simultaneously.
ibaCom-L2B-x-8 Manual PROFIBUS GSD Data and L2B Operating Modes The data to be measured from the PROFIBUS is defined using the GSD data files which must be registered on the DP Master. Each slave processor can be configured to one of the following modes: Integer format 2 x 32 analog / digital channels Real...
Manual ibaCom-L2B-x-8 11.1 GSD Files in Scope of Delivery Depending on DP-master system or data type, the following gsd-files which are part of the delivery should be used: Please note that there are new file names for the gsd-files. In the table below you'll find the old names in brackets.
ibaCom-L2B-x-8 Manual 11.1.1 iba_0F01.gsd – 32 Integer Inputs This mode is used to read up to 32 integer values and 32 digital signals from the PROFIBUS (OUT 72 Bytes). 11.1.1.1 DP-Master Output data OUTPUT DATA Contents Remark Byte no. Offset Status not used Status...
Manual ibaCom-L2B-x-8 11.1.2 iba_0F02.gsd – 32 Real Inputs This mode is used to read up to 32 real values and 32 digital signals from the PROFIBUS (OUT 136 Bytes). 11.1.2.1 DP-Master Output data OUTPUT DATA Contents Remark Byte no. Offset Status not used Status...
ibaCom-L2B-x-8 Manual 11.1.3 iba_0F04.gsd – 28 Real Inputs This mode is used to read up to 28 real values and 32 digital signals from the PROFIBUS (OUT 120 Bytes) from a Simatic S7 as PROFIBUS master. Due to limita- tions of the S7 real data type only 28 values can be used. 11.1.3.1 DP-Master Output data OUTPUT DATA Contents...
32 Words (16-bit integer), Big Endian Motorola Analog input channel 31 Integer (2 byte), Big Endian Motorola Device-ID of FO transmitter see list of iba device-IDs FO message counter-B incremented by each new FO message, Bit 7 always = 1 11.1.4.3 GSD File...
32 Longs (Real), Big Endian Motorola Analog input channel 31 Real (4 byte), Big Endian Motorola Device-ID of FO transmitter see list of iba device-IDs FO message counter-B incremented by each new FO message, Bit 7 always = 1 11.1.5.3 GSD File...
28 Longs (Real), Big Endian Motorola Analog input channel 27 Real (4 byte), Big Endian Motorola Device-ID of FO transmitter see list of iba device-IDs FO message counter-B incremented by each new FO message, Bit 7 always = 1 Issue 3.2...
Page 27
ibaCom-L2B-x-8 Manual 11.1.6.3 GSD File GSD filename Remark ibaF0_b4.gsd Transfer in one block with SFC (S7-400) other masters ibaF0_b3.gsd Transfer in four blocks with SFC (S7-300) 11.1.6.4 Applications ibaLogic, system coupling, Simatic S7, TDC, Simadyn D Issue 3.2...
Manual ibaCom-L2B-x-8 Technische Daten Manufacturer iba AG, Germany Order no. ibaCom-L2B-4-8: 12.116200 ibaCom-L2B-8-8: 12.116300 Mechanical Short PCI card (32 bit, 5 V) Operating Temperature 32 °F to 122 °F (0 °C to 50 °C) Storage Temperature -13 °F to 158 °F (-25 °C to 70 °C) Transport Temperature -13 °F to 158 °F (-25 °C to 70 °C)
Koenigswarterstr. 44 90762 Fuerth Germany Phone: +49 911 97282-0 Fax: +49 911 97282-33 Email: iba@iba-ag.com Contact: Mr. Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www.iba-ag.com. Issue 3.2...