  • Page 1 Issue 2.3 2.2 en...
  • Page 2  iba AG 2009 all rights reserved. ibaFOB-4i-X - Manual V 2.3 en / ibaFOB A2/A1 We have checked that the contents of this manual match the hardware and software de- scribed here. However, deviations cannot be fully ruled out, so that we cannot assume any warranty should any deviations actually exist.
  • Page 3: Table Of Contents

    Installing the Card ............... 10 Removing the Card ..............11 Installation of drivers Windows XP ................12 System Integration Sample Topologies with ibaFOB-4i-X .......... 14 7.1.1 Operation for data acquisition ..............14 7.1.2 Operation with ibaLogic (Vibration Monitoring, Bearing Monitoring) ..14 7.1.3 Operation with ibaPDA-V6 in X-Mode............15...
  • Page 4 Page 4 Manual ibaFOB-4i-X Support and Contact  iba AG 2012...
  • Page 5: This Manual

     A reference to additional documentation or more in-depth literature. iba training courses Hint for training courses by iba concerning related products or subjects Copyright notice Windows is a registered trademark of Microsoft Corporation. Other product or company names mentioned in this manual may be brand names or reg- istered trademarks of the corresponding owner.
  • Page 6: Introduction

    On one hand these are devices from iba which care the "X" in the name and on the other hand system components of other manufacturers like ABB AC 800 PEC or Simatic TDC with LO5A interface.
  • Page 7: What's New

    What's new? The ibaFOB-4i-X and respectively the ibaFOB-2io-X and ibaFOB-2i-X card represent the new generation of iba's fiber optic PC boards. These boards extend the existing board family and will replace the previous ibaFOB-cards in long-term. The new boards are 100% compatible on the fiber optical bus side while in the PC the interface and dual port ram layout differ between the old and new boards.
  • Page 8: Scope Of Delivery

    Manual ibaFOB-4i-X Scope of Delivery The following components are included with the delivery. ibaFOB-4i-X device  Flat ribbon cable with four jacks for iba card interrupt synchronization  Manual  Safety Information Please consider the following safety advises: W A R N I N G! To avoid electrical shock during installation or uninstallation of the device disconnect the power supply from the computer before opening.
  • Page 9: System Requirements

    Please see http://www.iba-ag.com for further details on a properly outfitted workstation. Recommendation for operation of two ibaFOB-4i-X (= 8 FO-links) with 32 Mbit/s. Lower requirements, lower transmission rates or less links permit use of PCs with lower performance. Software Microsoft Windows 2000, XP or 2003 Server ...
  • Page 10: Installation / Uninstallation

    If more than o ne iba-card are used connect all iba cards with the synchroni- zation cable. Close the computer, connect the power supply and start it.
  • Page 11: Removing The Card

    Stop and switch off the computer, disconnect it from the power supply and open it. Release the screw in the front panel. Pull out the card off the PCI slot carefully and put in a safe place or conduc- tive plastic bag.  iba AG 2012...
  • Page 12: Installation Of Drivers

    Installation of drivers Windows XP The ibaFOB-4i-X cards comply to the plug and play conventions of Windows. After the first-time installation of the card and booting of the computer the hardware in- stallation wizard pops up and guides you through the next steps of the installation proc- ess.
  • Page 13 Manual Page 13 The system searches the driver software and installs it automatically. After, click on <Finish>. In the Windows device manager you can check if the card has been detected and in- stalled correctly.  iba AG 2012...
  • Page 14: System Integration

    Page 14 Manual ibaFOB-4i-X System Integration Sample Topologies with ibaFOB-4i-X 7.1.1 Operation for data acquisition Mode of operation F-Mode Transmission rate (FO) 3.3 MBit/s (input) Sample rate 1 Hz ... 1 kHz Sample time 1000 ms ... 1 ms Peripheral devices...
  • Page 15: Operation With Ibapda-V6 In X-Mode

    8A + 8D (768A+768D 512 ... 16 FO-link 96 devices in ring) Application Input Output Input Output Input Output ibaPDA-V6 ■ □ ■ ibaLogic ■ □ ■ ibaScope Alarm outputs, via ibaFOB-4o-X, Output signals via ibaFOB-4o-X  iba AG 2012...
  • Page 16: Device Description

    No jumpers or DIL switches, all parameters are software controlled (the switch on  top of the board is for iba internal use only); interrupt synchronization cable to con- nect multiple iba cards in one PC Dynamic reassigning of interrupt sources and interrupt generation (board and driver ...
  • Page 17: Views, Displays And Connectors

    Page 17 Views, Displays and Connectors Connector for ibaFOB-4o-X for monitoring of input signals Connector for ibaFOB-4o-X for output signals Power supply for Sync-i / Sync-o- modules Sync-IRQ-connector 7-Segment display LEDs (4 x) Receivers (4 x)  iba AG 2012...
  • Page 18: Front Side Elements

    (dot is off). 8.3.3 Fiber Optic Interface of ibaFOB-4i-X The ibaFOB-4i-X provides four ST type jacks (grey) for the fiber optic receivers.  If the card was configured for external synchronization, e. g. for operation with an ibaBM-SLM, the first (top) input channel needs to be connected with the external device for proper function (otherwise the whole PC process will be stopped).
  • Page 19: Expansion Modules

    512 analog and 512 digital in- put channels, with practically no delay. To do this connect the ibaFOB-4o-X to the ibaFOB-4i-X on the light grey 14-pin connec- tor. The ibaFOB-4o-X module mirrors the input and output signals.
  • Page 20: Fiber Optic Interfaces Of Ibafob-4O-X (Optional)

    For applications which require only two in-/output channels, the use of the ibaFOB-2io-X is recommended. If the module is used for mirror function then another iba system may be supplied with the same input signals, e. g. ibaPDA and ibaLogic. Therefore, connect the module with the light grey 14-pin connector on the ibaFOB-2io-X or ibaFOB-4i-X card.
  • Page 21: Configuration And Engineering

    9.1.1 Configuration of the Card If an ibaFob-2io-X or ibaFob-4i-X card is installed, you'll find an additional tab FOB in the General dialog. These settings apply to measurements with high data rate only. If you use the card in F- mode the settings are not relevant.
  • Page 22 If you mark the sub branches with the links you'll get further information about the proc- essors. There are different sets of information, depending on whether a link is operating in X- mode or F-/M-mode. a) Link operating in F-Mode (with ibaPADU-8)  iba AG 2012...
  • Page 23 If you open the "link"-branches you can see the connected devices (= modules). Each link is subdivided in eight groups of eight channels each (64 in total per link) which corre- sponds to the smallest information package in the ibaPADU-8 philosophy.  iba AG 2012...
  • Page 24: Module And Signal Configuration (F-Mode)

    In the signal tables you can give a name to the signals assign physical units and limit val- ues (Max, Min) or set the signals active or passive. The column Actual shows already in- coming values when an active device is physically connected.  Further information finds you in the manual ibaPDA-V6.  iba AG 2012...
  • Page 25: Module And Signal Configuration (X-Mode)

    FobFast module should be added to the corresponding link. The module type is only available if an ibaFob-2io-X or ibaFob-4i-X card is installed. Fob Fast modules can only be connected to links which are configured for high data rate mode.
  • Page 26 By selection of the link mode, i. e. data types, the signal tables of analog signals will be adjusted automatically. (Integer: Min / Max; Real: Gain / Offset)  iba AG 2012...
  • Page 27 The signal tables for the analog and digital signals will be adjusted automatically. Moreover, you may specify the position in the telegram and the datatype of each signal in the signal tables.  iba AG 2012...
  • Page 28 Link mode Address offset for digital signals 64 Int 0xC0 128 Int / 64 Real 0x140 256 Int / 128 Real 0x240 512 Int / 256 Real 0x440 1024 Int / 512 Real 0x840 1024 Real 0x1040  iba AG 2012...
  • Page 29 WORD, 2 Byte -value  DWORD, 4 Byte-value  BYTE, 1 Byte  FLOAT, 4 Byte floating point value (real)  It might be necessary to adjust the addresses after a change with respect to the data type.  iba AG 2012...
  • Page 30: Diagnosis

    The main branch General in the tree view, tab Interrupt Info, shows the interrupt counter. The counter iba-Interrupts must have 1000 increments per second! If not, the interrupt master is missing. In this case check the card settings. In the dialog box of the link level (see 9.1.1), tab Info, you can see if the communication between ibaFOB card and ibaPADU device is working by checking the baud rate value.
  • Page 31: Synchronization Of Several Boards

    Manual Page 31 Synchronization of Several Boards Shut down the computer, remove the power connection and plug in the other iba PCI cards. Connect the synchronization cable between the devices. This is now necessary because the PCI bus does not support any synchronization signal on the bus which is available at all slots simultaneously.
  • Page 32: Technical Data

    1,44 A / 5 V (without connected modules) FO-cable 62,5/125 µm Coupling ST Lean Max. distance of fiber optical cable between de- up to 2000 m (6,560 ft) vices (without repeater) Weight (incl. package/documents) 200 g  iba AG 2012...