IBA FOB-SDexp Manual

Interface board for simadyn d

Advertisement

Quick Links

ibaFOB-SDexp
Manual
ibaFOB-SDexp
Interface Board for SIMADYN D
Manual
Issue 1.1
Issue 1.1
3

Advertisement

Table of Contents
loading

Summary of Contents for IBA FOB-SDexp

  • Page 1 ibaFOB-SDexp Manual ibaFOB-SDexp Interface Board for SIMADYN D Manual Issue 1.1 Issue 1.1...
  • Page 2 Required corrections are contained in the following regulations or can be down- loaded on the Internet. The current version is available for download on our web site http://www.iba-ag.com. Protection note Windows® is a label and registered trademark of the Microsoft Corporation. Other prod- uct and company names mentioned in this manual can be labels or registered trade- marks of the corresponding owners.
  • Page 3: Table Of Contents

    ibaFOB-SDexp Manual Table of contents About this manual ................... 5 Target group ....................5 Notations ....................... 5 Symbols used ....................6 Scope of delivery .................... 7 Safety information................... 7 System requirements ..................7 Hardware ....................... 7 Software ......................7 Introduction ..................... 8 Application .....................
  • Page 4 “Active data channels” tab ................31 8.2.5 “Channels in system” tab ................31 8.2.6 “Memory view” tab ..................32 Synchronization of iba cards ............... 33 Important information ................... 33 Procedure ....................33 Technical data ....................34 10.1 Main data ..................... 34 10.2...
  • Page 5: About This Manual

    ibaFOB-SDexp Manual About this manual This manual describes in detail the configuration and use of the product ibaFOB-SDexp. Target group This manual addresses in particular the qualified professionals who are familiar with han- dling electrical and electronic modules as well as communication and measurement tech- nology.
  • Page 6: Symbols Used

     By an electric shock!  Due to the improper handling of iba software products which are coupled to input and output procedures with control function! If you do not observe the safety instructions regarding the process and the system or...
  • Page 7: Scope Of Delivery

    IBM-PC compatible computer with the following minimum configuration:  Pentium IV/3 GHz  At least one free PCIe 1.0-x1 compatible slot  512 MB RAM  >10 GB hard disk space  Please see http://www.iba-ag.com for further details. Software  ibaPDA Version 6.32.0 or higher Issue 1.1...
  • Page 8: Introduction

    Introduction Application The ibaFOB-SDexp PC card couples the iba Process Data Acquisition system ibaPDA with the Siemens control system SIMADYN D (SD). Therefore, the ibaFOB-SDexp must be connected to one of the free fiber optic links of the SIMADYN D CS12, CS13 or CS14.
  • Page 9: Characteristics

    ibaFOB-SDexp Manual Characteristics The card has the following characteristics:  PCI Express card for 1.0-x1 compatible slot  100% functional compatible with the predecessor ibaFOB-SD  Firmware update without dismounting the card  1 bidirectional fiber optic channel with 96 Mbit/s (ST coupling) ...
  • Page 10: Front View

    An additional software license “ibaPDA-Request-SD” is required in order to use the SD-/TDC request function. It must be enabled on the iba software dongle. The service function blocks required for the request function are included in the iba function block library FBAPDA. You will find the library on the DVD-ROM delivered with ibaPDA.
  • Page 11: Plug And Socket Connections

    ibaFOB-SDexp Manual Plug and socket connections 1 Sync connector (blue) Figure 3: Plug and socket connections Indicators 5.6.1 Device LEDs LEDs indicate the operational state of the card and fiber optic channels. On power on all LEDs are lit for a few seconds to prove their proper function. Status Indication (green) Off...
  • Page 12: 7-Segment Display

    Manual ibaFOB-SDexp 5.6.2 7-Segment display The 7-segment display shows the following information:  Horizontal line: After System switch-on until ibaPDA has initialized the board  Board-ID: After board was initialized  The decimal dot ON: Card is configured as an internal interrupt master ...
  • Page 13: Mounting And Dismounting

    5. Plug in the card carefully into a free PCIe slot and fix the card to the housing of the 6. If more than one iba card is installed connect all cards with one another by the flat ribbon cable (sync cable), see chapter 9 “Synchronization of iba cards”.
  • Page 14: Configuration

    Manual ibaFOB-SDexp Configuration Configuration on the control unit 7.1.1 SD-TDC-lite transmission channels When projecting the transmission channels, the following is to be observed:  The names of the channels are established and should not be used elsewhere. The names of the max. 16 transmission channels (from the perspective of the control) are as follows: Channel 1: M0PDADAT...
  • Page 15 ibaFOB-SDexp Manual Figure 4: Configuration transmission channel with CTV Issue 1.1...
  • Page 16 Manual ibaFOB-SDexp Figure 5: Configuration transmission channel with CTV_P Description of the CTV_P connectors: Connector Value Description Connection to board: Component name of CS14 resp. CP53M0 M0PDADAT Name of the transmission channel REFRESH channel mode Transmits the cycle of the time slice Telegram length in bytes Pointer on telegram buffer which must be connected to the PTR connector of the...
  • Page 17: Sd-Tdc-Lite Reception Channels

    7.1.2 SD-TDC-lite reception channels Note Though the current firmware version provides the reception channels, they are not yet supported by iba-Software. 7.1.3 Technostring The Technostring (TS) is a slow process data channel with which additional non-cyclical alphanumeric data that accompany the measurement can be transmitted to ibaPDA. The TS runs independently of the PDA data channels.
  • Page 18: Time Synchronization

    (<5 ms). This function block supplies a digital DCF77 signal with polarity 0=active. Put it on a bit of a SD-TDC-lite telegram. The function block is contained in the FBAPDA function block library of iba AG. (If you require more information, please contact the support of iba AG.)
  • Page 19: Configuration In Ibapda

    As a result this card will generate the inter- rupt for the other cards (Interrupt-Slaves). The interrupt will be transmitted to these iba cards via the synchronization cable (sync cable is included in delivery).
  • Page 20: Link Configuration

    You will find the key “SDE_BgtName” under HKLM\SYSTEM\CurrentControlSet\Service\PdaDrv.  BG name of FOB-SDexp link: With this name, iba FOB-SDexp logs in on the rack link as BG. The default setting is the ibaPDA license number, limited to 6 characters. Important note If there are several ibaPDA systems connected to a computer coupling, you have to enter different BG names.
  • Page 21: Configuration Of Data Modules

    ibaFOB-SDexp Manual Options:  Auto disable signals on broken links: If this function is activated, the measurement channels of the CPUs which do not an- swer are temporarily disabled. This occurs e.g. when a frame is switched off while ibaPDA starts acquisition. At the next start, they are active again. ...
  • Page 22 Manual ibaFOB-SDexp “General” tab “General” tab Figure 11: On the “General” tab, the following standard settings can be found:  Locked: The module can be locked to avoid unauthorized access to module settings.  Enabled: Data capturing for this module is enabled; data capturing for deactivated modules is not possible.
  • Page 23 ibaFOB-SDexp Manual “Analog” and “Digital” signal tables tab In the “Analog” and “Digital” signal tables you can specify the analog and digital signals which are received in the telegrams by the control. “Analog” tab Figure 12:  Name: Here you can enter a name for the signal. Two additional comments can be defined for each signal by clicking on the icon.
  • Page 24: Configuration Of Technostring

    Manual ibaFOB-SDexp 7.2.4 Configuration of Technostring If the card has been installed correctly the interface Simadyn-D should be available under Technostring. After adding a Technostring module you can enter the data that is needed for the Tech- nostring reception and the data processing. After entry of the standard parameters the following settings must be defined: ...
  • Page 25: Time Synchronization

    ibaFOB-SDexp Manual 7.2.5 Time synchronization If you want to synchronize the time with a SIMATIC TDC-CPU or a SIMADYN D-CPU, the following actions are necessary: Synchronization with DCF77 signal:  On the control side, configure the DCF77 time signal and put the bit in the binary scope of a SD-TDC-lite channel, see chapter 7.1.4 “...
  • Page 26 Manual ibaFOB-SDexp Figure 15: Calculation of the IEC 1131 time signal  Select the time synchronization with IEC 1131 in the ibaPDA I/O manager.  In the pick-lists “IEC 1131 time signal” and “Microsecond signal”, select the calcu- lated virtual signals “99:4 IEC time seconds” and “99:5 IEC time microseconds”. Figure 16: Time synchronization with IEC 1131 time signal Issue 1.1...
  • Page 27: Diagnostics

    ibaFOB-SDexp Manual Diagnostics The essential tools for diagnostics are integrated in the I/O manager of ibaPDA. General card diagnostics If you click on the data interface in the tree structure, the image of the card with essential information appears in the right part of the dialog window. “Configuration”...
  • Page 28: Memory View" Tab

    Manual ibaFOB-SDexp Important note An update of the firmware should only be executed after consulting the service and support department of iba AG. “Memory view” tab 8.1.3 Figure 18: Memory view Here five different memory regions of the ibaFOB-SDexp card are displayed as hexa- decimal codes and strings.
  • Page 29: System-Info" Tab

    ibaFOB-SDexp Manual When the link to the control is established, you can read system data from the system by a click on <Autodetect system info>.  For more details, please refer to chapter 7.2.2 “Link configuration”. “System-Info” tab 8.2.2 The “System info” tab provides information about the link from ibaPDA to the control. Figure 20: System information ...
  • Page 30: Timing" Tab

    Manual ibaFOB-SDexp “Timing” tab 8.2.3 Here you'll find information about access of the card to the SIMADYN D CPUs and the access of the card to the memory (DMA). Figure 21: Timing Timing These settings apply to the cycle times which are only relevant for the SD-TDC Request system.
  • Page 31: Active Data Channels" Tab

    ibaFOB-SDexp Manual “Active data channels” tab 8.2.4 Here you'll find a table with all data channels, showing information about the configured time class, the access time and the data size. Figure 22: Active data channels A double-click on a row with data opens the memory view for this channel (see also chapter 8.2.6 “Memory view”...
  • Page 32: Memory View" Tab

    Manual ibaFOB-SDexp The table can be structured hierarchically by moving column headers per drag & drop to the free section above. Figure 24: Channels, grouped by columns “Memory view” tab 8.2.6 The memory region “1: FPGA registers” of the ibaFOB-SDexp card is shown in the “Memory view”...
  • Page 33: Synchronization Of Iba Cards

    Always save your system configuration before changing hardware components. Procedure You should perform the following steps after you’ve installed the card: 1. Connect all iba cards with the synchronization cable using the blue plugs. Figure 25: Connecting multiple iba cards by sync cable 2.
  • Page 34: Technical Data

    Manual ibaFOB-SDexp Technical data Main data 10.1 Order No. 11.112701 Format/size PCI Express card Operating Temperature From 32 °F to 122 °F (from 0 ° C to 50 ° Storage Temperature From -13 °F to 158 °F (from -25 ° C to 70 °...
  • Page 35: Performance

    ibaFOB-SDexp Manual Performance 10.2 Extract from a test protocol ibaFOB-SDexp is connected to CP53M0. All channels are configured to CPU 555 in time slice T1 = 1ms. Act. Max. Max. No. of mea- Sample time No. of duration duration Duration per duration per sured values = 1ms...
  • Page 36: Support And Contact

    Koenigswarterstr. 44 90762 Fuerth Germany Phone: +49 911 97282-0 Fax: +49 911 97282-33 E-Mail: iba@iba-ag.com Contact: Mr. Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www.iba-ag.com. Issue 1.1...

This manual is also suitable for:

11.112701

Table of Contents