G-U ELTRAL K35 Assembly And Operating Instructions Manual page 36

Chain drive
Table of Contents

Advertisement

Available languages

Available languages

Assembly and operating instructions
ELTRAL K35 | ELTRAL K35 Synchro
Chain drive
24 V DC
with Eltral VAN
+
24 V DC
Cable
Colour
1
Black "1"
2
Black "2"
3
Black "3"
Connection for ELTRAL K35 Synchro - 24 V
The connecting cable of the drive is approx. 2.5 m long. If the distance between drive and wall
switch is more than 2.5 m, only the wires for the power supply can be extended.
The white and red cables must not be extended. They must be connected
ATTENTION
no more than 2.5 m away with the terminal included in the scope of delivery.
If the two drives are more than 5 m apart, there is no guarantee that the synchro-
nisation signal will be transmitted without errors.
The low through-voltage (5 V) makes a secure connection to a fully function-
ing electric contact essential.
NOTE
Important: The two cables (white and red) must be connected before the
synchronised drives are set in motion for the first time with the chain fully
º
inserted. Otherwise there could be communication problems between the
two drives.
ATTENTION
36
Function
Signal VAN
Never apply voltage at the red and white
cables (24 V / 230 V).
1
2
3
1
2
3
If, after connection, the running direction
is contrary to that of the arrows on the wall
switch, the wires 1 and 2 must be inverted
VAN
Drive
ATTENTION