Recommended safety devices and wires
Device
E100
Supply voltage 1~240V
MCB
35A
MCA
33.5A
FLA
27.1A
Power wire cross-section
3 x 10 AWG
Cable Nominal Voltage UL/CSA 600 V
Supply voltage 3~240V
MCB
25A
MCA
20.5A
FLA
16.7A
Power wire cross-section
5 x 12 AWG
Cable Nominal Voltage UL/CSA 600 V
Supply voltage 3~480V
MCB
15A
MCA
11A
FLA
9.1A
5 x 14 AWG
Power wire cross-section
Cable Nominal Voltage UL/CSA 600 V
IMPORTANT! The specification of cables and protections refers to unbounded arrangement of. One should always abide by the local laws and recommendations concerning device connection.
WING is equipped with a terminal strip adjusted to an appropriate thickness of wires.
Air curtain model
Terminals view
WING E100 240/1/60 EC
WING E100 240/3/60 EC
WING E100 480/3/60/HLD EC
WING E150 240/3/60 EC
WING E200 240/3/60 EC
WING E150 480/3/60/HLD EC
WING E200 480/3/60/HLD EC
WING W100 240/1/60 EC
WING W150 240/1/60 EC
WING W200 240/1/60 EC
WING C100 240/1/60 EC
WING C150 240/1/60 EC
WING C200 240/1/60 EC
WING E100-200
E150
E200
45A
55A
38.8A
49.8A
32A
40.6A
5 x 10 AWG
5 x 8 AWG
25A
30A
20.2A
26.7A
17.2A
22.1A
5 x 12 AWG
5 x 12 AWG
L1 – Power supply phase
L2 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – first heating stage controlled by applying
240VAC
L1 – Power supply phase
L2 – Power supply phase
L3 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – first heating stage controlled by applying
240VAC
L1 – Power supply phase
L2 – Power supply phase
L3 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – first heating stage controlled by applying
240VAC
L1 – Power supply phase
L2 – Power supply phase
L3 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – first heating stage controlled by applying
240VAC
L1 – Power supply phase
L2 – Power supply phase
L3 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – first heating stage controlled by applying
240VAC
L1 – Power supply phase
L2 – Power supply phase
– Ground
1L1 – N/C
L2 – N/C
2 – input signal form HMI to control on/off valve
9 – valve with actuator Control
L1 – Power supply phase
L2 – Power supply phase
– Ground
L1 – N/C
L2 – N/C
WING W100-200 and WING C100-200
Device
W/C100
Fan supply voltage 1~240V
MOP
15
MCA
1.9A
FLA
1.5A
Power wire cross-section
Cable Nominal Voltage UL/CSA 600 V
Terminals description and function
3 – second heating stage controlled by applying 240VAC
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
1L1 – connected internally
L2 – connected internally
3 – second heating stage controlled by applying 240VAC
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
L1 – connected internally
L2 – connected internally
3 – second heating stage controlled by applying 240VAC
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
1L1 – connected internally
2L2 – connected internally
3 – second heating stage controlled by applying 240VAC
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
1L1 – connected internally
L2 – connected internally
3 – second heating stage controlled by applying 240VAC
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
1L1 – connected internally
2L2 – connected internally
10 – valve with actuator control
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for 0-10VDC speed regulation
– connected internally
1L1 – connected internally
L2 – connected internally
Ai – 0-10VDC analog input for fan speed regulation
G – Reference ground for
– connected internally
1L1 – connected internally
L2 – connected internally
W/C150
W/C200
15
15
2.8A
4.4A
2.2A
3.5A
3 x 14 AWG
0-10VDC speed regulation