WING
W100-200
WING
E100-200
WING
C100-200
8.2. ELECTRIC AIR CURTAIN – WING E100-200
T
– temperature of air at the inlet to the device
p1
T
– temperature of air at the outlet from the device
p2
P
– heating output of the device
g
Parameters
T
[°F]
41
p1
P
[kW]
2/4/6
g
T
[°F]
46/51/59
p2
P
[kW]
2/4/6
g
T
[°F]
48/53/60
p2
P
[kW]
2/4/6
g
T
[°F]
51/60/69
p2
8.3. WING C100-200 – COLD AIR CURTAIN
Parameters
Fan speed
III
Qp [CFM]
1147
noise level [dB(A)]*
62
* The noise level has been measured within a 10 ft distance from the device; reference conditions: semi-open space – wall-mounted device.
Parameters
Maximum width of a single door for one
device
Maximum height of door
Heating output range
Maximum flow rate
Maximum temperature of heating
medium
Maximum working pressure
Water volume
Diameter of stub pipe connectors
Supply voltage
Power of the electric heater
Rated current of the electric heater
EC Engine power
EC engine rated current
Weight
IP
WING E100
50
59
68
III/1088[CFM]/59dB(A)*
2/4/6
2/4/6
2/4/6
4/8/12
55/60/68
64/69/77
73/78/86
48/53/59
II/824[CFM]/48dB(A)*
2/4/6
2/4/6
2/4/6
4/8/12
57/62/69
66/71/78
75/80/87
50/57/66
I/541[CFM]/44dB(A)*
2/4/6
2/4/6
2/4/6
4/8/12
60/69/78
69/78/87
78/87/96
55/66/78
WING C100
II
I
882
618
1883
49
45
63
unit of
W100
measure
in
39
ft
13 –
58
MBH
CFM
1089
°F
psi
in³
97
"
V/ph/Hz
kW
A
HP
0,27
A
1.5
lbs
47
-
WING E150
41
50
59
68
III/1854[CFM]/61dB(A)*
4/8/12
4/8/12
4/8/12
57/62/68
66/71/77
75/80/86
II/1206[CFM]/48dB(A)*
4/8/12
4/8/12
4/8/12
59/66/75
68/75/84
77/84/93
I/853[CFM]/43dB(A)*
4/8/12
4/8/12
4/8/12
64/75/87
73/84/96
82/93/105
WING C150
III
II
I
III
1324
882
2707
49
43
63
WING W100-200
WING E100-200
W150
W200
E100
59
79
39
12
7/20 or 14/20
34 – 109
58 –
160
1824
2589
1088
200
232
158
219
3/4
~240/1/(50/60)
or
~240/3/(50/60)
~240/1/(50/6
or
0)
~480/3/(50/60)
-
2 and 4
9 or
-
5/10/15 or
3/5/8
0,4
0,64
0,27
2.2
3.5
1.5
64
83
49
14
WING E200
41
50
59
III/2648[CFM]/62dB(A)*
6/9/15
6/9/15
6/9/15
6/9/15
48/50/57
57/59/66
66/68/75
75/77/84
II/1883[CFM]/48dB(A)*
6/9/15
6/9/15
6/9/15
6/9/15
50/53/60
59/62/69
68/71/78
77/80/87
I/1265[CFM]/45dB(A)*
6/9/15
6/9/15
6/9/15
6/9/15
53/59/69
62/68/78
71/77/87
80/86/96
WING C200
II
I
2001
1377
49
45
WING C100-200
E150
E200
C100
C150
59
79
39
59
13
13/41
20/51 or
-
or
30/51
27/4
1
1854
2648
1147
1883
-
-
-
-
-
-
-
-
~240/3/(50/60) or
~240/1/(50/6
~480/3/(50/60)
0)
4 and 8
6 and 9
-
10/20/30 or
15/22/37 or
-
-
5/10/15
8/11/19
0,4
0,64
0,27
0,4
2.2
3.5
1.5
2.2
67
86
42
56
20
68
EN
C200
79
2707
-
0,64
3.5
72