Siemens SIMATIC S7-1500 Function Manual page 79

Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Open User Communication
6.5 Setting up Open User Communication via TCP, ISO-on-TCP, UDP and ISO
6. Select an existing connection description DB in the "Connection data" drop-down list or
for configured connections select an existing connection under "Connection name". You
can also create a new connection description DB or a new configured connection. Later,
you can still select other connection description DBs or configured connections or change
the names of the connection description DBs in order to create new data blocks:
– You can also see the selected data block at the interconnection of the CONNECT
– If you have already specified a connection description DB for the connection partner
– If you edit the name of the displayed data block in the drop-down list, a new data block
– Changed names of a data block must be unique in the context of the communication
– A connection description DB must have the structure TCON_Param, TCON_IP_v4 or
– A data block cannot be selected for an unspecified partner.
Additional values are determined and entered after the selection or creation of the
connection description DB or configured connection.
The following is valid for specified connection partners:
– ISO-on-TCP connection type
– Connection ID with default of 1
– Active connection establishment by local partner
– TSAP ID
The following is valid for unspecified connection partners:
– TCP connection type
– Partner port 2000
The following applies for a configured connection with a specified connection partner:
– TCP connection type
– Connection ID with default of 257
– Active connection establishment by local partner
– Partner port 2000
The following applies for a configured connection with an unspecified connection partner:
– TCP connection type
– Local port 2000
78
input parameter of the selected TCON, TSEND_C or TRCV_C instruction.
using the CONNECT parameter of the TCON, TSEND_C or TRCV_C instruction, you
can either use this DB or create a new DB.
with the changed name but with the same structure and content is generated and
used for the connection.
partner.
TCON_IP_RFC, depending on CPU type and connection.
for S7-1200/1500: E0.01.49.53.4F.6F.6E.54.43.50.2D.31
Function Manual, 11/2019, A5E03735815-AH
Communication

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents