Siemens SIMATIC S7-1500 Function Manual page 210

Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

6. Now import the namespace "http://www.euromap.org/euromap83/"
To do so, click the "Import XML" button again in the "Information model" area.
Select the file "Opc_Ua.EUROMAP83.NodeSet2.xml".
Result: SiOME imports the XML file and shows the namespace
"http://www.euromap.org/euromap83/" in the "Namespaces" area.
7. Now import the namespace "http://www.euromap.org/euromap77/"
To do so, click the "Import XML" button again in the "Information model" area.
Select the file "Opc_Ua.EUROMAP77.NodeSet2.xml".
8. Create your own namespace for your project.
To do this, right-click in the "Namespaces" area on "OPC UA Modelling Editor Project" or
on "Namespaces" and select "Add Namespace".
SiOME opens the "Add Namespace" dialog.
9. Enter the name of a new namespace.
The "YourCompany.org" namespace is used in the example.
SiOME now also displays the new namespace:
Figure 9-35
10. Create an instance from the root object type IMM_MES_InterfaceType of the Companion
specification Euromap 77.
To do so, in the "Information model" area, right-click the "DeviceSet" directory and select
"Add Instance".
SiOME displays the "Add Instance" dialog.
11. For "Name", enter a meaningful name for your instance.
In the example, enter "IMM_Manufacturer_01234".
For "TypeDefinition", select "IMM_MES_InterfaceType".
This object type is the root object type of Euromap 77: If you generate an instance of this
object type, then use the Euromap 77 once in the address space of your OPC UA server.
Communication
Function Manual, 11/2019, A5E03735815-AH
Display of the namespace in SiOME
OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
209

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents