Testing The Receiver Channels With The Bite Matrix Functionality - Simrad ME70 Instruction Manual

Hide thumbs Also See for ME70:
Table of Contents

Advertisement

5
In the ME70 user interface, open the
The
Port Monitor
chosen serial line port.
6
Make sure that the sensor data are received.
7
Make sure that the information from the sensor is displayed on the top bar in the ME70
user interface.
8
Repeat the test for all the serial ports using different datagrams for heading, position,
speed and distance.
9
Stop the test.
a
Close the Sensor Simulator program.
b
Disconnect the serial line cable from the computer.
c
Turn off the computer.
Result
Requirements
The Processor Unit accepts the serial line information on all relevant COM
ports.
The sensor data is shown in the ME70 presentation.
Date and signature:
Testing the receiver channels with the BITE
Matrix functionality
The
page allows you to monitor the average signal values or signal phases from each
Matrix
of the channels and transducer elements in the ME70. The presentation is provided on a
matrix corresponding to the element locations in the transducer. For receiver testing, the
ME70 must be operational, and both operational and BITE parameters must be known.
Prerequisites
The ME70 has been set up with its hardware units connected as specified in the ME70
Installation manual.
• If applicable: The transducer is replaced with a dummyload.
• The ME70 system is turned on and operates normally.
307958/H
Port Monitor
dialog box allows you to study the communication stream on the
Testing the ME70 operational functionality
dialog box.
Results
27

Advertisement

Table of Contents
loading

Table of Contents