Functional Testing - Winkhaus blueSmart ETB-IM Operating Manual

Electronic door handle for internal doors
Table of Contents

Advertisement

Operating manual
Step 10
8

Functional testing

Functional testing
Aug. Winkhaus GmbH & Co. KG ∙ Hessenweg 9 ∙ 48157 Münster ∙ T +49  251  4908 - 0 ∙ zutrittsorganisation@winkhaus.de ∙ www.winkhaus.de
ETB-IM
Step 10: Screw the handle with the spindle with the grub screw using the
Allen key (size 3).
Step 11: Set the time for the electronics using the programming device and
the adapter cable A5 (see Operating manual programming device).
Then carry out a function test using authorised identification media
with the door open (see 8 Functional testing).
Step 12: Where applicable, mount the profile cylinder cover rosettes with
the corresponding M5 screws.
• Set the time via the programming device and the adapter cable type A5
(round
programming
12 Troubleshooting).
• Hold the identification medium against the interaction surface as shown.
• A brief signal tone sounds when access is authorised. The door handle is
engaged for about 3 seconds. The door can be opened.
• A longer signal tone sounds when access is not authorised. The door
handle remains in neutral position.
• Activate permanent release by presenting the identification medium for
approx. 3-5 seconds. The LED lights up green twice and 2 short signal
tones sound at the same time. The door handle is engaged permanently
(until the next auto off where applicable). The door is then permanently
accessible.
• Deactivate the permanent release by presenting the identification medium
for approx. 3-5 seconds. The LED lights up green twice, 2 long signal tones
sound at the same time and the permanent release is reset. The door
handle returns to neutral position.
• The system and/or door can be commissioned once all functions have
been tested.
13
adapter).
A
Warning!
The time on the electronics must be set before carrying
out the functional test. See the manual for the pro-
gramming device for more information. The functions
may only be tested while the door is open. The door
can be opened at any time with the handle on the
B-side. The handle on the A-side is in neutral position.
valid
time
is
signalled
(see