Page 1
Electronic Automatic Locking System Operating Manual After installation please pass on these instructions to the end customer in accordance with Informati- on. Disclosure Act stipulated in the Law on Product Liability!
3.6.2.1 Control of additional applications (only integra 2) page 31 3.6.2.2 Control of automatic door opener (integra 1 and 2) page 31 Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 4
Power supply page 43 Antenna/Reader unit page 43 Wireless remote control page 43 Cable transition KÜ-T ... page 45 Accessories page 46 Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
To ensure the intended use: • the information and instructions required for this purpose have to be passed on to the respective persons; Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Read the operating manual and keep it easily accessible for future reference. After installing the door pass it on to the end customer. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
INPUT: 100 - 240 V AC; 50/60 Hz OUTPUT: 12 V DC; 2 A Figure 2-1: Electronic automatic locking system with accessories Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 10
„Open” button Flush-type box Handle remaining components recommended for use, or should be used alternatively Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Ü supply of the locking sy- stem will have the mounted motor housing incl. signal (floating contact) for automatic door opener Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Center keep for latch and dead bolt of PVCu/Vinyl, aluminum and wood/Composite entrance doors. Select the respective keeps according to the profile systems in the current program manual (see above). Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
EAV and finger scanner ekey home integra, sash part 1 m Kabel + 8-pole plug for control unit ekey home integra Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
From the outside the door is opened via the access control system (transponder, wire- less remote control). NOTICE! VdS acceptance: Only with VdS-tested access control systems! Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 16
You have to connect the following parts directly with the door opener when using/connecting a door opener: varistor at AC/free-wheeling diode at DC Reason: protection of the relay from wear. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
47 mm [1.850”]! Errors Troubleshooting Technical specifications Accessories Figure 3.1-1: Dimensions for the electronic automatic locking system Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 18
Check the door euro groove for sprue so that the free motion of the rod is not impeded! b) It is imperative to use always with a Lever/fixed pad handle set (lever inside, door knob outside). Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Install the cable for example within the glazing chamber towards the motor housing; install the rest of the cable for example within the hollow section. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 20
Cover plate F16 50 [1.968"] 9 [0.354"] 3 [0.118"] Sash part Cover plate F20 Figure 3.2-2: Routing dimensions for cable transition KÜ-T-STV Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
If the operating voltage has been applied (start-up), the motor brings the locking points Maintenance into the neutral position. and care Errors Troubleshooting Technical specifications Accessories Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
* with potential free contact control systems * ** no necessary screened cable Figure 3.3.1-1: General connection diagram Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Connect the cable of the antenna to the reader/control unit. • We recommend: Lay a reserve pipe from the antenna to the reader unit. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 24
(plus) (minus) Recommendation: power supply flush-type box or junction 12V DC/2A box for cable connection N PE 230V/50Hz Figure 3.4-2: Installation of the transponder reader Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
„Auxiliary antenna/ANT“ (not required) 1 2 3 4 5 „Auxiliary antenna/GND“ (not required) Figure 3.5.1-1: Terminal assignment of the wireless receiver Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 26
(plus) (minus) Recommendation: power supply flush-type box or junction 12V DC/2A box for cable connection N PE 230V/50Hz Figure 3.5.1-2: Installing the wireless receiver Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Insert the circuit board of the remote according to figure 3.5.2-2 and connect it to the control of the additional application (for example to the garage door control unit). Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 28
• Deactivation by actuating the remote after about 1 sec. it will be deactivated control once more. automatically. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
If several appliances (like access control + EAV) are operated together in the same description door, you can use a common power supply with min. 1,5A for EAV additionally the power requirement of the access control system. For this you need a stabilized 12V DC direct current (chapter 2: product description power supply).
Page 30
Assembly connection between control unit ekey home integra 2 and motor housing EAV 4 . For this connect the wires of the cable of 2 m (included in deli- very of the integra - EAV 5 ) with terminal X6 (see figure: 3.6.1-1, detail A). After this plug-in the blue plug into the motor housing.
- EAV 2 m 5 . Programming • Make a connection from the motor housing EAV (blue plug) to the control unit ekey home integra (length of min. 2 m) via this cable. Maintenance If necessary disconnect the cable respectively remove the cable covering.
• Once the transponder chip is close enough to where it can read the information, communication is established contact free. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Ü Teach Transponder chip Action Acoustic Signal Result Pass the programmable teach-in mode card over the antenna short, every 0.5 seconds „active“ Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 34
In this state you cannot open the door via transponder chip or card; rather you will have to re-progamm the transpon- der chip. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
A red LED Accessories button B NOTICE! Keep the buttons pressed until you hear the acoustic signal at the receiver! Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 36
(of a programmed remote „completely deleted“ (non short, 3 times control) simultaneously programmed remote control) Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 37
Activate the desired button of the remote control while the LED is lit up • As long as the LED is lit, you can program additional remote control buttons. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 38
Displaying the occupied memory units: • Press and hold the P1 button of the receiver until the green LED lights up. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Press and hold the P1 button for about 2 seconds. • When the green LED lights up, release the P1 button. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
• Clean electronic parts only in a dry state. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
• Operating forces too • Check installation (keep high, faulty installation alignment, air gap, etc.) Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 42
Does not operate • Remote battery dead • Replace battery in with remote control, remote control red LED is not illu- minating. Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
2 to the power of 64 („Rolling Code“) Frequency of the local oscillator: 6.6128MHz Intermediate frequency: 10.7MHz Sensitivity (to receive signals): -115dB Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 44
Input impedance: 50Ohm Maximum memory capacity: 85 codes for remote control Power supply: 12/24V AC/DC Closed-circuit current: 15mA On-load current: 33/48mA Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
4 m [4.374 yd] and care Max. voltage: 24V DC Max. switching current: 2A per connection line/wire Errors Troubleshooting Technical specifications Accessories Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
(the second button at the remote control can be used for this purpose) STV-Wireless receiver F01 214 289 7 Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Berkeser Str. 6 Accessories D-98617 Meiningen Germany and authorized by: Meiningen, 09 July 2004 ..................p.p.a. Dr. Warnow Title: Technical Director Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de Subject to technical changes...
Page 48
Aug. Winkhaus GmbH & Co. KG Berkeser Straße 6 D-98617 Meiningen T + 49 (0) 3693 950-0 F + 49 (0) 3693 950-134 www.winkhaus.de tuertechnik@winkhaus.de...
Need help?
Do you have a question about the EAV and is the answer not in the manual?
Questions and answers