Shutdowns And Alarms; Spare Parts - Northern Lights M773LW3 Operator's Manual

Hide thumbs Also See for M773LW3:
Table of Contents

Advertisement

SHUTDOWNS AND ALARMS

1. Generator sets have shutdown systems to stop the
engine in the event of high water temperature, low oil
pressure or high exhaust temperature.
a. Other alarms and shutdowns are available as
optional equipment.
Contact your Northern Lights dealer for
troubleshooting assistance if not equipped with
optional gauge panels.
2. If optional gauge panels are installed, do the
following when your warning or shutdown system is
activated:
a. Engage the preheat switch to check the temperature
gauge, if installed.
b. If above 205°F (96°C), use the Troubleshooting
Guide on page 32 to isolate the cause of the
overheat.
DANGER
!
Do not open the filler cap when the engine is
warm. Opening a warm filler cap can cause
severe burns.
c. Make repairs. Restart your generator set after the
temperature gauge registers below 200°F (94°C).
d. Watch the temperature gauge regularly and
turn off the unit if the temperature rises above
205°F (96°C) on Marine units. Repeat trouble-
shooting.
3. If shutdown is activated and the temperature gauge
shows temperature within normal temperature range:
a. This shutdown could have happened because of
a too high exhaust temperature. This could have
been caused by a damaged impeller or a partially
blocked sea water strainer. Check the sea water
strainer first. If it is clear, then check the
condition of the sea water pump impeller.
b. Check the engine crankcase oil level.
c. If the oil level is low, fill with recommended
lubricating oil and restart. Watch the oil pressure
gauge carefully and shut off the engine if it does
not show a normal reading (20-60 PSI) after a
few seconds of operation.
d. If the oil level is normal, DO NOT restart the
engine. Call your dealer for assistance.
Updated 8-14-19
Operating Procedures

SPARE PARTS

Northern Lights recommends that you keep the
following spare parts on hand for field service. The
parts are available from your local Northern Lights
dealer. Marine models have optional "On-Board-
Kits," a handy box that contains the most common
parts you will need.
Northern Lights standard spare parts kit (P/N
38-08605)*
contains:
a. Primary and secondary fuel filter elements
b. Oil filters
c. Air filter element
d. Drive belt
e. Thermostat and gaskets
f. Raw water pump impeller with gaskets
g. Water pump cover o-ring
h. Rocker arm cover gasket
Intended for long-distance cruisers, Northern Lights
world class spare parts kit (P/N 38-08612)* contains:
a. Primary and secondary fuel filter elements
b. Oil filters
c. Air filter element
d. Drive belt
e. Thermostat and gaskets
f. Raw water pump impeller with gaskets
g. Water pump cover o-ring
h. Rocker arm cover gasket
i. Impeller kit with gasket
j. Injector assembly
k. 12v glow plug
l. Gasket set
m. Fuel lift pump and mtg. gasket
n. O-ring
o. Relay, SPDT 12v 50A
p. Workshop manual
*- For use with M773LW3 and M773LW3G generator sets with heat
exchangers. Consult your Northern Lights dealer for your unit's
specific spare parts requirements.
OM773LW3 11/20
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

M773lw3g

Table of Contents