Figure 5: Series 1-B Generator Control Panel
Figure 6: Series 3 Generator Control Panel
Updated 8-14-19

Control Panels

1. SHUTDOWN BYPASS-PREHEAT SWITCH
There are two functions built into this switch:
1. Preheats the fuel before beginning the starting
process. Press switch 10 seconds before
attempting start-up.
2. Bypasses the safety shutdown feature during
starting process. Keep switch engaged while starting
engine and for up to five seconds afterwards, allowing
oil pressure to build beyond shutdown set point.
2. ENGINE CONTROL SWITCH
To start the engine, hold this switch in the START
position until the engine is running.
NOTE: Excessive cranking of marine sets equipped
with water lift muffler systems can cause engine
damage.
After the engine starts, release the switch and it will
return to RUN position. To stop the engine, hold the
switch in the STOP position.
NOTE: The rocker switch is used on Series 1 panels
only, and has a light that glows when the set is running.
3. HOUR METER
Keeps track of engine running time.
4. OIL PRESSURE GAUGE
Shows the oil pressure in the engine lubricating system.
5. WATER TEMPERATURE GAUGE
Registers the temperature of the cooling water.
6. D.C. VOLTMETER OR AMMETER
When the engine is stopped, the voltmeter indicates the
condition of the battery. When the engine is running,
the voltmeter indicates the voltage output of the
alternator.
OM773LW3 11/20