Fuels And Appliances; General Installation Regulations - Firepower Clearline AKW Installation Instructions And Maintenance Manual

Twin-wall chimney
Table of Contents

Advertisement

FUELS AND APPLIANCES

CLEARLINE AKW conforms to BS EN1856-2. It is an all stainless
steel insulated chimney system designed to be used with solid fuel,
biomass, oil or gas, and with both condensing and non-condensing
boilers. Clearline AKW has been tested to have a working
temperature of 600°C. (200°C on condensing systems fitted with
seals). Chimneys installed in accordance with these instructions will
comply with British Standards.
Failure to follow the installation instructions could cause
FIRE, CARBON MONOXIDE POISONING, OR DEATH.

GENERAL INSTALLATION REGULATIONS

Chimney installation should be carried out by a competent person.
We recommend the use of HETAS approved installers for solid fuel
applications. If installation is carried out by a non HETAS registered
installer, the installation must be certified by a local Building Control
inspector. Planning permission may be required, and reference
should be made to the local Building Control Department.
VENTILATION
It is very important that sufficient air for combustion and ventilation
is provided to the room containing the appliance to enable correct
and efficient working of the appliance and chimney system.
CARBON MONOXIDE ALARMS
A carbon monoxide alarm must be provided in the room where the
solid fuel or gas appliance is located.
3