Offset Charts - Firepower Clearline AKW Installation Instructions And Maintenance Manual

Twin-wall chimney
Table of Contents

Advertisement

 It is recommended that chimneys serving solid fuel appliances
be swept as frequently as necessary, but at least once a year.
 Chimney flue cleaning and inspection require the use of
appropriate equipment – under no circumstances should
chemical cleaners or mild steel tools be used to sweep stainless
steel chimneys.
 We would advise that monthly checks are carried out to ensure
that there is no build up of any deposits in the connecting flue
pipe or chimney system.

OFFSET CHARTS

Internal Flue Diameter
45 Degree
30 Degree
15 Degree
mm
Bend
Length
250mm
500mm
1000mm
-
250mm
500mm
1000mm
-
250mm
500mm
1000mm
125mm
X
Y
-
122
295
269
442
445
619
799
972
68
275
172
454
297
670
552
1103
34
260
88
460
153
701
282
1184
150mm
X
Y
130
313
276
459
453
636
803
991
77
287
180
466
305
682
555
1115
35
268
89
468
154
710
283
1192