INSULATION COVER PLATE
Used to close off a flue system to cover any exposed insulation material. Can be
used when using a generic cowl or when no rain cap is required.
ACCESSORIES
DRAUGHT STABILISER
Helps to regulate the draught within the chimney, used with a flue length with a door
eg: 90 degree T.
A COMMON CAUSE OF CHIMNEY RELATED FIRES IS THE FAILURE TO
MAINTAIN THE REQUIRED AIR GAP BETWEEN THE OUTER SURFACE OF
THE FLUE AND COMBUSTIBLE MATERIALS.
IT IS VITAL THAT THIS FLUE PIPE SHOULD BE INSTALLED WITH THE
CORRECT MINIMUM CLEARANCES AS SPECIFIED IN THESE
INSTRUCTIONS.

MAINTENANCE AND CHIMNEY CLEANING

INSPECTION
 Chimney sweeping should be carried out by competent
persons. The chimney should be designed to allow for easy
inspection and cleaning.
 An inspection elbow or a 90° or 135° Tee with tee cap can form
a suitable inspection point (unless cleaning/inspection can be
done through the appliance).
 To aid cleaning, sufficient distance should be left between
changes of direction to permit the safe passage of cleaning
brushes within the system.
Code:02-***-104
Code:15-***-007
21