Firepower Clearline AKW Installation Instructions And Maintenance Manual page 17

Twin-wall chimney
Table of Contents

Advertisement

PENETRATION COMPONENTS
SOLID FIRESTOP PLATE
Mainly used in gas or oil installations. For solid fuel installations, can only be
used to go through a floor in a single storey building into a non-habitable cold
loft space.
WHITE VENTILATED FIRESTOP PLATE
Used when penetrating a ceiling or floor in a domestic installation. The Ceiling
Support Kit comprises of two of these and a Floor Support Band. Can be used
with the Ventilated Firestop Cover Plate. The pair of Ventilated Firestop Plates
can support 3metres of flue above the ceiling, and 1.5metres below.
WHITE FIRESTOP COVER PLATE
This is powder coated to match white ceilings. Used to cover existing Ventilated
Firestop Plate, still allowing enough free air around the flue and the boxing in
above. The plate includes magnets and spacers to ensure enough free air
movement.
Code:02-***-070
Code:02-***-073
Code:15-***-075
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents