Audible Alarm
The TRED30-16R is fitted with a beeper, which can be enabled to
provide extra feedback when an alarm event has been registered. This
function is enabled when configuring the recorder with LogTag
Analyzer, please see the
Standard Configuration Options
previous page or the
Audible Alarm
Please note, that continual activation of the audible alarm will
reduce the working life of the battery. When an alarm event is
triggered, the alarm should be cleared as soon as possible.
The alarm will sound once every two seconds for the first 24 hours. To
preserve battery life, the interval at which the alarm sounds will
increase by 2 seconds each time the clock passes midnight after the
initial 24 hour period (i.e. the alarm will sound every 2 seconds
between 24 and 48 hours, depending on when during the day the
alarm triggered, then every 4 seconds for a day, then every 6 seconds
and so on).
Once the interval has reached 10 seconds, it will no longer increase.
Note: The interval will increase, even if the alarm is re-triggered!
Please see more information about
previous page
Advanced Configuration Options
Select Advanced Options for additional configuration settings. These
settings decide how some of the elements are displayed on the screen
and set certain options specific to the TRED30-16R.
Figure 4: TRED30-16R advanced configuration screen
Parameters that influence the appearance of the display are
Pause alarm/statistics processing (see
l
Temperature display unit (see
l
Switch off display after 30 seconds (Power save, see
l
on page 11)
showing the number of days on the display, for which statistical
l
data have been collected (see
Collected
on page 11)
Parameters influencing specific behaviour of the TRED30-16R are
clear and reset alarm when the
l
pressed
leaving the alarm turned on, even if readings return to the normal
l
temperature range again
allowing the user to stop the recorder with the
l
button
START
/CLEAR/STOP
allowing the user to reset the recorder with the
l
button
START
/CLEAR/STOP
Enter the desired options and click
returns you to the standard configuration dialogue.
Page 6 of 16
on the
above.
Alarm Re-triggering
on the
Paused Readings
on page 10
Display Overview
on page 7)
Power Save
Total Number of Days Statistics
button is
START
/CLEAR/STOP
OK
to accept the new values. This
®
TRED30-16R Product User Guide, Revision 1.3, copyright © 2004-2016,
®
LogTag
Recorders
. All rights reserved.