Lil Global Data I/O Function Blocks - Siemens Moore 353 User Manual

Process automation controller
Table of Contents

Advertisement

Configuration Overview
on the local faceplate when that loop is selected and also how loop data will be mapped on the Modbus or LIL
network interface. Each LOOP can have one controller function block (i.e. ID, ONOFF, PD, PID, or PIDAG).
A/M ....................Auto/Manual
ACS01-99...........ARCCosine (V1.3)
ADD01-99 ..........Addition
AG3 ....................AGA3 (V1.3)
AG7 ....................AGA7 (V1.3)
AG8 ....................AGA8 (V1.3)
ALARM.............Alarm
AND01-99 ..........AND Logic
ASN01-99...........Arcsine (V1.3)
ATN01-99 ..........Arctangent (V1.3)
ATD01-99 ..........Analog Trend Display (V1.3)
BATOT ..............Batch Totalizer
BATSW..............Batch Switch
BIAS...................Bias
CHR01-99..........Characterizer
CMP01-99..........Comparator
COS01-99 ..........Cosine (V1.3)
DAM01-99 .........Deviation Amplifier
DIV01-99 ...........Division
DNC01-99 ..........Divide by N Counter
DTM01-99 .........Dead Time Table
DYT01-99 ..........Delay Timer
E/I.......................External/Internal Transfer
ESL ....................Events Sequence Logger (V1.3)
EXP01-99...........Natural Exponentiation (V1.3)
EXT01-99 ..........Exponentiation (V1.3)
FTG01-99 ..........Falling Edge Trigger
GB01-99.............Gain & Bias
HLD01-99 ..........Hold
ID........................ID Controller
LL01-99 .............Lead/Lag
LMT01-99..........Limit
LN_01-99 ...........Natural Logarithm (V1.3)
LOG01-99..........Logarithm Base 10 (V1.3)
MTH01-99 .........Math
MUL01-99 .........Multiplication
NND01-99 ..........NAND Logic
NOR01-99..........NOR Logic
NOT01-99 ..........NOT Logic

2.4 LIL GLOBAL DATA I/O FUNCTION BLOCKS

These function blocks are available in the quantities indicated within each loop when the optional LIL Network
board is installed. The total number of global function blocks will be limited by the number of global channels
available. A controller has 256 channels. Each global data block occupies one global channel. In addition, each
configured Control LOOP occupies 5 channels, each configured Sequencer LOOP 6 channels, and the Station itself
the first 7 channels. See Section 6 for more information on network communications.
AIL01-99............Analog Input_LIL
AOL01-99 ..........Analog Output_LIL
DIL01-99 ...........Discrete Input_LIL
DOL01-99 ..........Discrete Output_LIL
2-2
ODC ...................Operator Display for Controllers
ODS....................Operator Display for Sequencers
ODA (V2.2)........Op Disp for Analog Ind. & Alarm
ODD (V2.2)........Op Disp for Discrete Ind & Control
ODP (V2.2) ........Operator Display for Pushbuttons
ONOFF ..............ON OFF Controller
OR01-99.............OR Logic
ORSL .................Override Selector
OST01-99...........One Shot Timer
PB1SW...............PB1 Switch
PB2SW...............PB2 Switch
PB3SW...............PB3 Switch
PCOM................Phase Communication (V1.3)
PD.......................PD Controller
PID .....................PID Controller
PIDAG ...............PIDAG Controller
PRSEQ...............Program Sequencer
QHD01-99..........Quickset Hold
RATIO...............Ratio
RCT01-99 ..........Repeat Cycle Timer
RLM01-99 .........Rate Limiter (V3.0)
ROT01-99 ..........Retentive On Timer
RSF01-99 ...........RS Flip-Flop
RTG01-99 ..........Rising Edge Trigger
RTT01-99 ..........Real Time clock Trip (V2.0)
SCL01-99...........Scaler
SEL01-99 ...........Signal Selector
SETPT ...............Setpoint
SIN01-99 ............Sine (V1.3)
SPLIM ...............Setpoint Limit
SRF01-99 ...........SR Flip-Flop
SRT01-99...........Square Root
SUB01-99...........Subtraction
TAN01-99 ..........Tangent (V1.3)
TH01-99.............Track & Hold
TOT01-99 ..........TOTalizer (V2.3)
TSW01-99..........Transfer Switch
XOR01-99..........Exclusive OR Logic
UM353-1