Technology Data Blocks; Principle Of Motion Control Instructions - Siemens SINAMICS G120 Application Description

Sinamics g: speed control of a (startdrive) with (to) via profinet or profibus with safety integrated (via terminal) and hmi
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

3 Principle of Operation
3.2 Interaction of motion control instructions and technology objects
Only an appropriate chronological order of the calls of the motion control
instructions in the control program of the SIAMTIC S7-1500 allows you to use the
TO in a technologically useful way.
Therefore, it is recommended to use a sequencer in the user program from which
the motion control instructions according to the PLCopen standard are called.
3.2.2

Technology data blocks

After generating the technology objects, technology data blocks are automatically
created. The TO status and more TO-typical information is entered in these blocks;
for an axis, this is, for example, the current position
The technology data block can be accessed like a normal data block.
3.2.3

Principle of motion control instructions

Figure 3-2
Basically, all motion control instructions work on the following principle:
The Axis input specifies to which TO and therefore to which axis the motion
control instruction is to be sent.
A rising edge at the Execute input triggers the job. The job type depends on
the motion control instructions used.
The status outputs of the FB (Busy, Done, CommandAborted and Error)
display the job status.
While a job is active, the Busy output parameter displays the value TRUE;
when the job is complete, Busy displays the value FALSE.
The other output parameters display the status for at least one cycle. While
the Execute input parameter is set to TRUE, these status messages are
displayed on a latching basis.
4
Positioning axes only
SINAMICS G120 as a Speed Axis on the S7-1500
V1.0a, Entry ID: 78788716
While the Execute input is set to TRUE, the job status is displayed at
the status outputs of the FB (Busy, Done, CommandAborted and
Error).
If the Execute input parameter is set to FALSE while the job is not yet
complete (Busy = TRUE), the Done output (or Error or
CommandAborted) will be set to TRUE for only one cycle once the job
is complete!
4
and velocity.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s7-1500Step 7 v12 sp1 upd2Startdrive v12 sp1