Taking measurements
Example of a measurement log for measuring the synchronisation overlap
Measur-
Base station A
ing
point
A
B
-50 dBm/100%
C
-42 dBm/100%
D
–60 dBm/100%
E
----
The result of the measurement is that the signal strength is sufficient for synchronisation
everywhere. Base station E only receives base station D with sufficient quality.
Here, a sensible synchronisation hierarchy would be:
Sync level 1
Base station C
Sync level 2
Base stations A, B and D
Sync level 3
Base station E
34
Base station B
Base station C
-52 dBm/100%
-40 dBm/100%
-48 dBm/100%
-46 dBm/100%
-----
-48 dBm/100%
-68 dBm/94%
----
Base station D
Base station E
-58 dBm/100%
----
----
-70 dBm/92%
-50 dBm/100%
----
-64 dBm/100%
-62 dBm/100%