Gigaset N870 IP Pro Site Planning And Measurement Manual page 32

Multicell system
Table of Contents

Advertisement

Taking measurements
Example of a measurement log for the cell of a base station
Measuring
Base station A
point
1
–60 dBm/100%
2
-65 dBm/98%
. . .
. . .
. . .
. . .
9
-73 dBm/70%
If you have measured the cells of multiple base stations, the results may look like this, for example:
Measur-
Base station A
ing
point
1
–60 dBm/100%
2
-50 dBm/98%
3
-65 dBm/100%
4
-48 dBm/100%
5
-55 dBm/98%
6
-65 dBm/100%
7
-68 dBm/96%
8
-55 dBm/98%
9
10
11
12
13
14
15
16
17
18
19
20
Measuring points where two base stations are received with at least –65 dBm are located in an over-
lap zone of the two base stations in which a handover is possible (highlighted grey in the table).
32
Base station B
-50 dBm/100%
-59 dBm/100%
-46 dBm/98%
–60 dBm/96 %
-52 dBm/98%
-63 dBm/100%
-48 dBm/98%
Base station C
-65 dBm/100%
-57 dBm/100%
-42 dBm/100%
-46 dBm/98%
-40 dBm/100%
–60 dBm/98%
-43 dBm/100%
Base station D
-52 dBm/100%
-42 dBm/100%
-56 dBm/100%
-50 dBm/98%
-53 dBm/100%
–60 dBm/98%

Advertisement