Measuring the synchronisation overlap of neighbouring base stations
For the base stations to be able to synchronise, the signal strength between two neighbouring
base stations must not be less than –70 dBm. This value applies in good environmental conditions,
¢
P. 27.
Proceed as follows for the measurements:
¤
Leave the measuring base station at the last measuring site and proceed with the handset
to the planned position of a base station that is to synchronise with the first base station.
In order to reliably assess the synchronisation, you must be located, with the handset, at the
exact position of the planned base station (use a ladder to measure at the correct height,
if necessary).
¤
Check whether the signal is within the limit of -70 dBm at 100% frame quality. If this is not the
case, you should change the location of the base station until this minimum requirement is met.
¤
Install the measuring base station at this location and take the measurements as for the
first position.
¤
Enter the results in the plan and the measurement log.
¤
Now take this measurement for all planned assembly locations.
B
A
C
Taking measurements
D
E