c) Connecting the LED strip to the control unit
• Connect the 4-pin connection of the LED
strip to the corresponding 4-pin socket of the
control unit.
Make sure that the labels on the connections match (the arrow symbol on the socket
of the control unit must point to the label "+" on the LED strip).
• The plug connection can be protected from unintentional disconnection by using a strip of
adhesive tape.
d) Connecting the wall plug transformer
• Connect the round low voltage plug of the wall plug transformer to the corresponding round
socket on the control unit.
• Connect the wall plug transformer to a proper mains socket of the public supply network.
e) Inserting the battery into the IR remote control
• Open the battery compartment of the IR remote control and insert a battery of type "CR2025",
paying attention to the correct polarity (pay attention to plus/+ and minus/-). Close the battery
compartment again.
• The battery needs replacing if the range of the IR remote control decreases or if the control
unit no longer responds to the remote control.
Basic functions of the IR remote control
Point the LED on the front of the IR remote control at the IR receiver of the control unit and
press the corresponding button.
"ON" button
Switches the LED strip on
"OFF" button
Switches the LED strip off
"
" button
Increases the brightness (not possible in all lighting programmes)
"
" button
Reduces the brightness (not possible in all lighting programmes)
"W" button
Light colour "White"
"R" button
For selection of the light colour "red"
"G" button
For selection of the light colour "green"
"B" button
For selection of the light colour "blue"
12 colour buttons
For selection of 12 predefined light colours
The four buttons "FLASH", "STROBE", "FADE" and "SMOOTH" can be used to start the
predefined lighting programmes. Depending on the lighting programme, you can also change
the brightness with the button "
" or "

Maintenance and cleaning

• Apart from the occasional battery change for the IR remote control, the product is
maintenance-free.
The built-in LED bulbs are permanently installed; they cannot be replaced.
• Before you clean the product, disconnect it from the mains voltage. Pull the wall plug
transformer from the mains socket.
• The outside of the product should only be cleaned with a clean, soft, dry cloth.
Do not use aggressive cleaning agents or chemical solutions for this could damage
the housing (discolouring) or impair the operation.
Disposal
a) General
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
Remove any inserted batteries and dispose of them separately from the product.
b) Batteries and rechargeable batteries
You as the end user are required by law (Battery Ordinance) to return all used
batteries/rechargeable batteries. Disposing of them in the household waste is
prohibited.
Batteries containing hazardous substances are labelled with this symbol to
indicate that disposal in the domestic waste is forbidden. The designations for the
heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on
(rechargeable) batteries, e.g. below the trash icon on the left).
Used batteries can be returned to collection points in your municipality, our stores or wherever
batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
" (not possible in all lighting programmes).

Technical data

a) General
Total power consumption .................... approx. 24 W
Ambient conditions ............................. Temperature 0 °C to +45 °C,
b) LED Strip
Length................................................. 5 m
Cross-section ...................................... (W x H) 10 x 3 mm
Number of LEDs ................................. 150 x RGB
Weight ................................................ approx. 160 g
c) Wall Plug Transformer
Operating voltage ............................... 220 – 240 V/AC, 50/60 Hz
Output ................................................. 12 V/DC, 3 A
d) Control unit
Operating voltage ............................... 12 V/DC
Required current ................................. min. 3 A
Dimensions ......................................... 35 x 50 x 22.5 mm (W x L x H)
Weight ................................................ 25 g
e) IR remote control
Power supply ...................................... 1x battery of type CR2025
Dimensions ......................................... 52 x 85 x 7 mm (W x H x D)
Weight ................................................ 20 g (incl. battery)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE.
air humidity 10% to 80% relative, not condensing
*1227385_r_v1_0916_02_jh_m_en

Advertisement

Table of Contents
loading

This manual is also suitable for:

5mac862wA542631

Table of Contents