Installation; Safety; Appliance Description - AEG IR Premium 1500 IP 44 Operation And Installation

Ir short wave radiant heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

6. Safety

Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
6.1
General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regula-
tions and instructions.
Note
When installing the appliance in rooms with a bath
and/or shower, observe the safety zone in accord-
ance with the details on the type plate.

7. Appliance description

7.1
Standard delivery
The following are delivered with the appliance:
◦ Wall mounting bracket (incl. fixing screw and nut)
7.2
Special accessories
◦ IR Funk Dimmer 2000
◦ IR Funk W
◦ IR Funk S
◦ IR Funk Multi BiDi
◦ IR Strebenklemme (brace clamping bracket)
8. Installation
8.1
Installation conditions and
preparations
CAUTION Injury
!
Install the appliance out of the reach of children.
◦ Never install this appliance on or below combustible
materials.
◦ Never install the appliance directly below a socket.
◦ Install the appliance on the wall or ceiling.
◦ Observe the specified minimum clearances (see
chapter "Specification / Dimensions"). This appli-
ance gives off radiated heat. Therefore ensure that
there are no objects between the appliance and the
person or objects to be heated, such as furniture, for
example.
◦ Wood ceilings may become hot even if the minimum
clearances are observed. Dark spots or fine shrink-
age cracks on wooden ceilings may therefore occur.
Installation – for qualified contractors
8.2 Power supply
WARNING Electrocution
Carry out all electrical connection and installation
work in accordance with relevant regulations.
WARNING Electrocution
Ensure the appliance can be separated from the
power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
An external socket must be able to be isolated from
the power supply across all poles.
Always equip the supplying power circuit of the ap-
pliance with an RCD (nominal earth leakage current
≤ 30 mA).
Note
Observe the type plate. The specified voltage must
match the mains voltage.
Only connect the appliance to a correctly installed mains
socket.
We recommend a dedicated fuse for this appliance (see
chapter "Specification / Data table"). From 3600 W up-
wards, only ever connect one appliance per fuse.
8.3 Appliance installation
Note
Check in chapter "Specification / Data table" wheth-
er you are able to install the appliance vertically or
horizontally.
» Secure the mounting bracket on the wall or ceiling
using suitable fixing materials.
» Secure the appliance to the mounting bracket using
the screw and nut provided.
» Route the power cable from the appliance either to-
wards the back, top or bottom.
8.4 Adjusting the tilting angle
The tilting angle can be adjusted over a range of 100°.
We recommend a setting of 45°.
CAUTION Burns
If the appliance is already in use, let it cool down
before adjusting the tilting angle.
» Undo both screws on the pivot hinge.
» Set an appropriate tilting angle.
» Retighten the two screws again.
Material losses
!
Ensure that the appliance does not come into con-
tact with the power cable.
8.5 Dismantling
» Pull the mains plug out of the socket.
CAUTION Burns
First allow the appliance to cool down before trans-
porting or storing it.
» Remove the appliance from the wall mounting
bracket.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir premium 1500 ip 44 wIr premium 1500 ip 44 a234790234791234792

Table of Contents