4-10 Commands

4-10-1 HG-S series command list

The following table shows the command parameters that are used to read and write controller
settings and statuses and to send operation commands to controllers.
For details on each item, refer to the "HG-S User's Manual".
Command
0x0001
0x0002 to 0x0004
0x0005
0x0006
0x0007 to 0x000F
0x0010
0x0011
0x0012
0x0013
0x0014
0x0015
0x0016 to 0x0017
0x0018
0x0019
0x001A
0x001B
0x001C
0x001D
0x001E
0x001F
0x0020
0x0021
0x0022
4-34
Attribute
Name
R
Status/Error
-
System reserved
W
Controller reset
W
Initialization (RESET)
-
System reserved
R
Judgment value (JUDGE.V)
Normal measured value
R
(NORM.V)
R
Calculated value (CALC)
Sensor head measured value
R
(HEAD.V)
R/W LOW set value (LO.SET)
R/W HIGH set value (HI.SET)
-
System reserved
R/W Hysteresis (HYSTER)
-
System reserved
R/W Output operation (OUTPUT)
-
System reserved
R
Output state
R
Input state
W
Execute bank load (LOAD)
W
Execute bank save (SAVE)
R/W Key lock (LOCK)
R/W Eco mode (ECO)
Maximum value during P-P
R
measurement
Attributes (R: Read, W: Write, R/W: Read/Write)
Response/Setting parameter
When status is normal = 0
When error occurs = Error code
Do not use.
Reset the controller. (Master unit only)
Return the settings to the factory default state.
Do not specify "0".
Do not use.
Integer indicating minimum resolution units of controller.
-1999999 to 1999999
Integer indicating minimum resolution units of controller.
-1999999 to 1999999
Integer indicating minimum resolution units of controller.
If a calculated value is not set, the judgment
value is output.
-1999999 to 1999999
Integer indicating minimum resolution units of controller.
-1999999 to 1999999
Integer indicating minimum resolution units of controller.
-1999999 to 1999999
Integer indicating minimum resolution units of controller.
-1999999 to 1999999
Do not use.
Integer indicating minimum resolution units of controller.
0 to 1999999
Do not use.
0: N.O.
1: N.C.
Do not use.
bit0: External output 1 (0 = OFF / 1 = ON)
bit1: External output 2 (0 = OFF / 1 = ON)
bit2: External output 3 (0 = OFF / 1 = ON)
The high bit is "0".
bit0: External input 1 (0 = OFF / 1 = ON)
bit1: External input 2 (0 = OFF / 1 = ON)
bit2: External input 3 (0 = OFF / 1 = ON)
The high bit is "0".
Bank numbers 1 to 3 are loaded
Bank numbers 1 to 3 are saved
0: Key lock OFF
1: Key lock ON
0: Eco mode OFF
1: Eco mode ON
Integer indicating minimum resolution units of controller.
If the measurement mode is not P-P or P-P/2, a
judgment value is output.
-1999999 to 1999999
WUME-SCHG1C-4