Communication Unit System - Panasonic SC-HG1-C User Manual

Cc-link communication unit for digital displacement sensors
Table of Contents

Advertisement

System Configuration

2-1 Communication unit system

This product is a communication unit for the purpose of monitoring sensor ON / OFF output and
detected quantities using CC-Link communication between controllers and a master station.
This product can connect a maximum of 15 controllers (one master controller, 14 slave controllers).
The CC-Link operation mode can be set to Ver. 1.10 or Ver. 2.00 (2 stations x8 / 4 stations x4)
using the mode setting switch.
The power that drives this product is supplied from a connected controller / master controller.
Dedicated cable certified by CC-Link
Partner Association
(shielded 3-conductor twisted-pair cable).
(Please obtain separately)
To master
station
MS-DIN-E end plate (optional)
or commercially available fitting
2-2
To power supply
SC-HG1-C
To power supply
Controller - master
(optional)
Controllers - slave (optional)
(Maximum of 14 units are
connectable)
WUME-SCHG1C-4