CC-LINK Network Communication

4-11-2 Reading measured waveforms

The following procedure is used to read waveforms.
■ Flowchart of measured waveform reading
1. "Waveform read setting" (WRITE)
The command selects a waveform type (measured waveform).
2. "Waveform read setting" (READ)
The command saves the current waveform information into the controller.
3. "Waveform read data" (READ)
The command reads waveform data.
4. "Measured value at the time of waveform reading [HEAD.V]" (READ)
The command reads the measured value that is associated with the wave-
form when the waveform is saved.
5. "Edge information at the time of waveform reading" (READ)
The command reads the edge information that is associated with the
waveform when the waveform is saved.
6. "Edge position at the time of waveform reading"(READ)
The command reads the edge position associated with the waveform that
is saved.
4-56