2.2 Modifications by the user

The user must not make any modifications to the Schaeffler SmartCheck device. The user may only make settings
on the device itself or via the Schaeffler SmartWeb, Schaeffler SmartUtility Light or Schaeffler SmartUtility software.
The user bears responsibility for any further modifications! Should you detect a fault with your Schaeffler
SmartCheck device, please contact our Support team.

2.3 Technical data

·
The SmartCheck device must not be used in measurement voltage categories II, III or IV!
·
Cover any M12 connections that are not in use with the plugs supplied. This is the only
way to ensure that the degree of protection is maintained.
Internal sensors
Vibration
Temperature
Measurement
Measurement functions
Diagnostic methods
Characteristic values (time range and frequency range)
Defined characteristic
values
Calculated characteristic
values
Signal processing
Frequency resolution
Measurement resolution
Frequency range
Low-passes
High-passes (demodulation
only)
Memory
Program and data
Inputs and outputs
Inputs
Outputs
Interfaces
Control elements
Display elements
Communication
Acceleration sensor (piezoelectric sensor)
Frequency range: 0.8 Hz–10 kHz
Measurement range: ±50 g
Measurement range: -20 to +70°C
Acceleration
Speed and path by integration
System temperature
Process parameters (e.g. speed, load, pressure)
Time signal, demodulation, spectrum and trend analysis, speed and frequency tracking
DIN/ISO 10816
RMS, frequency-selective RMS, constant component, peak, peak-to-peak, crest factor,
Wellhausen count, condition guard
Other user-defined characteristic values are possible.
1600, 3200, 6400 or 12800 lines
Min. line width 0.0039 Hz at 50 Hz (depending on low-pass)
24 bit (A/D converter)
0.8 Hz–10 kHz
50 Hz–10 kHz (50 Hz, 100 Hz, 200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz)
750 Hz, 1 kHz, 2 kHz (other filters on request)
64 MB RAM, 128 MB flash
2 analogue inputs (0-10 V/0-24 V/0-20 mA/4-20 mA), frequency range 0-500 Hz, 12 bit
1 digital input (0-30 V, 0.1 Hz-1 kHz)
1 analogue output (0-10 V/0-20 mA/4-20 mA), 12 bit
1 switching output (open collector, max. 1 A, 28 V)
Optional galvanic isolation between inputs and outputs
2 capacitive buttons (learning mode, alarm reset, restart, factory settings)
1 LED for displaying the status and alarms
1 LED for confirming buttons
2 LEDs for displaying communication
Ethernet 100 Mb/s
RS485 (not currently supported)
Product description