NE40E
Hardware Description
Item
Typical power consumption
Typical heat dissipation

1.8.4.7 AC PEM

The AC PEM is used to connect the AC power supply. Each PEM provides four power inputs.
The two terminals on the right side are connected to the power supply plane on the client side,
and the two terminals on the left are connected to the power supply plane on the client side.
The AC PEM is fully configured with the entire system. The system has two PEMs.
Appearance
Figure 1-49 shows the appearance of an AC PEM.
Figure 1-49 AC PEM
Panel
Table 1-54 Interface Description
Interface
Name
C20 AC
socket
Input upstream requirements
Issue 01 (2018-05-03)
The AC power system supports 200-240 V AC power. It supports 110 V dual-live-wire inputs but not
110 V AC single-phase inputs. If 110 V dual-live-wire inputs are used, the voltage must range from 180
V to 264 V.
240V HVDC power system, the input voltage range from 192 V to 288 V DC. 380V HVDC power
system, the input voltage range from 260 V to 400 V.
Description
Input interface for
220 V AC power
supply
Supports 220 V AC input. In 110 V AC scenarios, the dual-live wire input mode can be
used, as Figure 1-50 shown in.
Specification
182 W
590.5 BTU/hour
Applicable power cable terminals
C19
1 Hardware Description