Hardware Description
Indicator
RUN
ALM
Table 1-64 Interfaces
Interface Name
NEG(-)
RTN(+)
Table 1-65 Switches
Switch Name
ON OFF
Technical Specifications
Item
Dimensions (H x W x D)
Weight
Rated voltage
Voltage range
Maximum current
Typical power consumption
Typical heat dissipation
1.8.5.3 EPS200-4850A
AC power input is converted into regulated DC power by an AC/DC converter.
Issue 01 (2018-05-03)
Color
Description
Green
Indicates normal power output. If the indicator is steady on,
the power output is normal.
Red
Power failure indicator. If the indicator is steady on, it
indicates the following:
The lightning protection link of the power module
failed.
The power modules do not have input power.
Description
-48 V power input interface
BGND power input interface
Description
Rated current of the air-break: 60A.
Used to control AC power input.
Specification
220 mm x 105 mm x 58 mm(8.66 in x 4.13 in x 2.83 in)
1.1 kg(2.43 lb)
-48 V/-60 V
-38.4 VDC to -72 VDC
70 A
1.0 W
3.2 BTU/hour
1 Hardware Description