Yamaha CP5 Reference Manual page 32

Yamaha electronic keyboard user manual
Hide thumbs Also See for CP5:
Table of Contents

Advertisement

Zone Edit Screen
Settings are made on the Zone Edit screen when your CP5 or CP50 is to be used as a master key-
board. By setting the ZoneSw parameter to "on", you can split the keyboard into a maximum of four
zones, and if these zones are then assigned to the built-in Tone Generator and external musical
devices, it will be possible to play them all from the stage piano's keyboard. To access the Zone
Edit screen, press Knob 3 (ZoneEdit [PUSH]) from Page 2 of the Common Settings screen.
Press the [COMMON] button
Edit Sequence
buttons
On-screen name
Page
(and full name)
All
Zone
pages
1
ZoneSw
(Zone Switch)
2
Target
TransCh
(Transmit Channel)
3
Octave
Trnsps (Transpose)
4
NoteLimit
(Note Limits)
5
MIDIBankSel
(MIDI Bank Select)
6
MIDIPgmChg
(MIDI Program
Change)
7
Volume
Pan
32
CP5/CP50 Reference Manual
Navigate to Page 2 using the [
Press Knob 3 (ZoneEdit [PUSH])
This parameter is used to select the zone to be edited. As Page 1 affects all
zones, however, this parameter's setting is displayed as "COMMON" on that page.
Setting values: zone1, zone2, zone3, or zone4
This parameter is used to turn on and off splitting of the keyboard into four distinct
zones.
This parameter is used to select a destination for control signals from the current
zone.
Setting values: off ......... The current zone will be disabled.
TG......... The current zone will control the built-in Tone Generator.
MIDI...... The current zone will control another musical device
connected to the stage piano.
both ...... The current zone will control both the built-in Tone Gen-
erator and another musical device connected to the
stage piano.
This parameter is used to select a MIDI transmit channel for control signals from
the current zone. A setting may be made only when Target is set to "MIDI" or
"both".
Setting values: 1 to 16
This parameter is used to transpose the current zone in units of one octave.
Setting values: -3 to +0 to +3
This parameter is used to transpose the current zone in units of one semitone.
Setting values: -11 to +0 to +11 (semitones)
These parameters are used to define a keyboard section for the current zone.
Specifically, Knob 2 is used to set the lowest note; Knob 3, the highest.
Setting values: C-2 to G8
Set by turning Knobs 2 and 3, these parameters can be used to specify bank
select MSB, bank select LSB, and program change values to be sent to the corre-
sponding external musical device as MIDI messages. In this way, you can select a
sound to be played by the current zone. It should be noted that the actual sounds
produced will depend on the type of musical device being used. Meanwhile, if
these parameters are set to "off", no bank select MSB, bank select LSB, or pro-
gram change values will be send as MIDI messages from the zone in question.
Setting values: MIDIBankSel...... off, 0 to 127
MIDIPgmChg..... off, 1 to 128
This parameter is used to adjust the volume of the current zone.
Setting values: 0 to 127
This parameter is used to adjust the stereo panning of the current zone.
Setting values: L63 to C to R63
PAGE] and [PAGE
L
Description
Internal Design of the CP5 & CP50
Reference
Left & Right Parts
R
[VOICE]
R
[PRE-AMP]
]
R
R
[MOD-FX]
R
[PWR-AMP] (CP5 only)
R
[LEFT1]/[LEFT2]/[RIGHT1]/
[RIGHT2] (CP5)
[LEFT]/[RIGHT] (CP50)
R
[COMMON]
Song Setting Area
R
[SONG SETTING]
[RECORD]
R
TRACK Part
R
[TRACK]
MIC INPUT Part
[MIC INPUT] (CP5 only)
R
Settings for All Parts
R
[REVERB]
Settings for All Performances
[MASTER COMPRESSOR]
R
R
[UTILITY]
R
[FILE]
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp50

Table of Contents