12 Specific data IO-Link (pin 6)
12.4.31 Operating times
The current valve travel times can be read out with the Operating times parameter.
In-
Sub
Off-
Access
dex
-
set
Rights
In-
dex
0x62
1
0
RO
2
8
RO
Description of parameter values
Index name
Operating times
12.4.32 Drive sets
The traverse speed and force of the actuator can be influenced with the Drive sets parameter when the valve is initialized.
In-
Sub
Off-
Access
dex
-
set
Rights
In-
dex
0x90
1
0
R/W
2
8
R/W
Description of parameter values
Index name
Drive sets
Speed
Actuator size
AG0 and AG1
Force settings
Actuator size
AG0 and AG1

12.5 Events

The following IO-Link events can be transmitted.
Event
Device Hardware Fault
Motor Unable To Move
Device Temperature Over-Run
GEMÜ 543
OPEN / CLOSE (Code AE)
Lengt
Index name
h
8 bits
Operating times
8 bits
Parameter
Values
Open
0 to 255
0 to 25.5 s
Close
0 to 255
0 to 25.5 s
Lengt
Index name
h
2 bits
Drive sets
3 bits
Parameter
Values
Speed
1 ... 3
Force
1 ... 6
Setting parameter
Setting parameter
App/Disapp
App/Disapp
App/Disapp
Parameter
Type
Open
uint:8
Close
uint:8
Read out operating time (in tenths of seconds) from end
position CLOSED to end position OPEN.
Read out operating time (in tenths of seconds) from end
position OPEN to end position CLOSED.
Parameter
Type
Speed
Force
Select the speeds for the average travel range.
Set the force for the average travel range and for sealing.
Preset at the factory depending on the valve type.
1 (43 %)
2 (71 %)
3 (100 %)
1
6
Mode
Error
Error
Warning/Error
58 / 70
Default
Values
0
0 to 255,
0 to 25.5 s
0
0 to 255,
0 to 25.5 s
Description
Default
Values
3
1 ... 3
-
1 ... 6
Description
Average speed in m / s
1.6
2.3
3.0
Force
Minimum force
Maximum force
Type
Code
0x5000
0x8CE0
0x4210