2. Safety Regulations
Attention: Drain distillation residues only when the green lamp on the
Attention: Check the liquid level before opening the still door
Attention: Do not dispose of distillation residues in the sewer system
Requirements for the owner and operating personnel
According to the legal stipulations of the German accident prevention
regulations (BGR 500 chapter 2.14), special knowledge is required for the
operation and maintenance of drycleaning systems. A person with this
special knowledge must regularly be present during the operation of
drycleaning systems.
As a person / body who runs a plant one is obliged to have the refrigerating plant of the
dry cleaning machine inspected annually with regard to tightness.

2.4 Repair Work

Only skilled workers with suitable protection devices and work tools are authorized to carry out repairs.
Make sure that there are no solvent emissions.
During repair and cleaning work:
Turn main switch off.
Close the stop valves on the supply lines (steam, condensate and compressed air).
Make sure that the system cannot be turned on without permission (close off and
put up a sign "DO NOT TURN ON - REPAIR WORK " ).
Always remove the main fuse when working on the electrical system.
Use only original fuses to replace defective ones.
When working on pneumatic control parts, make sure that there is no pressure in the system.
Only specially trained refrigeration technicians are authorized to make repairs to the refrigeration unit.
All spare parts used must comply with the technical standards set by the manufacturer.
4
still is lit.
The collecting tank must hold the amount that is expected
to be drained and must be temperature and solvent-
resistant at up to 150 °C (302 °F).
or normal garbage. You must dispose of these residues
according to country-specific regulations on special waste.