Eqs2 Elite Blast Pressure Setting - Graco EcoQuip2 EQm Operation, Repair, And Parts

Vapor abrasive blast
Table of Contents

Advertisement

14. To set the MediaTrak (ZD), slowly adjust the
abrasive metering valve (T) while the abrasive
is blasting from the nozzle to reach the desired
setpoint.
0
0
0
0
0
8
8
0
0
0
0
NOTE: You may have to wait 1–2 minutes for the
NOTE:
NOTE:
abrasive material to reach the nozzle.
NOTE:
NOTE:
NOTE: Use a piece of test material similar to
what you will be blasting. Always start as gently
as possible and then increase the blast force as
necessary to clean without doing any damage to
the substrate.
3A3489A
0
8
8
EQs2 Elite
Elite Blast
Blast Pressure
EQs2
EQs2
Elite
Blast
1. Turn both blast pressure regulators all the way
in (CW).
2. Blast with nozzle one and nozzle two and record
the blast pressure from the blast pressure gauge.
3. Blast with nozzle one and set the blast pressure
at or below the recorded blast pressure from step
2.
4. Blast with nozzle two and set the blast pressure
at or below the recorded blast pressure from step
2.
5. Continue from step 13 on
Setting Up the Equipment, page 13