CHAPTER 13 - EXTERNAL MODULATING CONTROL
HEATING SETTING
DHW Operation
Demand Type
DHW Boiler Setpoint
DHW Setpoint
DHW Warmstart Setpoint
DHW Warmstart Hysteresis
DHW On Differential
DHW Storage Adder
DHW Post Pump Time
DHW Priority Timeout
DHW Priority
DHW Call Blocking
DHW to CH Call Blocking
Antilegionella Function
BOILER SETTING
EXALT Solo
Lockout Temp.
Modbus Address
Flex. Relay 1(CH)
Flex. Relay 2(DHW)
Flex. Relay 3(P3)
Flex. Relay 4(ERR)
Flex. Relay 5(Flame)
Flex. Relay 6(P4)
On Lockout, Blocking
Error Relay
Pump PWM Minimum
Ignition Level
Mix Zone High Limit
Appliance Setting
Altitude Setting
78
CTRLMax Factory Settings (cont'd)
FACTORY
DEFAULT
EXALT Solo
EXALT Combi
Enabled
Enabled
Thermostat
N/A
168°F [75°C]
168°F [75°C]
140°F [60°C]
140°F [60°C]
N/A
125°F [52°C]
N/A
30°F [17K]
6°F [3K]
18°F [10K]
27°F [15°K]
N/A
2 Minutes
2 Minutes
Off
Off
Enabled
Enabled
1 Minute
1 Minute
1 Minute
1 Minute
Disabled
Enabled
FACTORY
MINIMUM
DEFAULT
SETTING
EX-
ALT Combi
210°F [99°C]
0=BCST
0=BCST
CH1
DHW
CH1/CH2/DHW
ERROR
FLAME
CH2
and Warning
30%
1%
Varies by model
114°F [45°C]
68°F [20°C]
Varies by model
0 ft
0 ft
MINIMUM
MAXIMUM
SETTING
SETTING
96°F [35°C]
188°F [87°C]
68°F [20°C]
168°F [75°C]
86°F [30°C]
140°F [60°C]
9K
36K
4°F [2°C]
18°F [10°C]
10°F [5°C]
54°F [30°C]
Off
30 Minutes
Off
120 Minutes
0 Minute
30 Minutes
0 Minute
30 Minutes
MAXIMUM
EZ SETUP RESET
SETTING
247
100%
176°F [80°C]
20,000 ft
EZ SETUP RESET
INSTALLER RESET
Thermostat
6°F [3K]
27°F [15°K]
Enabled