CHAPTER 9 - CTRLMAX OPERATION
9.8.
Domestic Hot Water EZ Setup
Domestic Hot Water EZ Setup allows the installer to quickly customize the Domestic Hot Water settings for the application
EZ Setup
DHW EZ Setup
Select DHW Demand
Thermostat
Sensor
96°F
EZ Setup
DHW EZ Setup
Select DHW Demand
Thermostat
Sensor
DHW Storage Setpoint
68°F
58
- EXALT Solo Units
DHW
Boiler Setpoint
168°F
188°F
140°F
168°F
DHW Priority Timeout
O
O
120 min.
EZ Setup Complete
DHW EZ setup is complete.
Additional changes can be made in
the Installer Menu if required.
Press OK to return to EZ Setup Menu
Select DHW Demand prompts the installer to select how a DHW
Demand is generated.
When Thermostat is selected in Select DHW Demand, a domestic
hot water call from an aquastat or dry contact switch will enable the
EXALT with a fixed setpoint for a domestic hot water call. After Ther-
mostat is selected, the DHW Boiler Setpoint screen appears.
Default: Thermostat
DHW Boiler Setpoint prompts to enter the fixed boiler setpoint
temperature during a domestic hot water call.
Touch the
or
soft keys to adjust the temperature setpoint
to store the setting. The DHW Priority Timeout
then touch
screen then appears (see below).
Default: 168°F
[75°C].
When Sensor is selected in Select DHW Demand, use of an (optional)
Indirect Water Heater Sensor is required. The EXALT monitors the DHW
storage temperature and generates a DHW call whenever the tem-
perature drops below the DHW storage setpoint by 6°F [3°C].
DHW Storage Setpoint prompts to enter the DHW Storage Set-
point temperature.
Touch the
or
soft keys to adjust the temperature setpoint then
to store the setting. The DHW Priority Timeout screen
touch
then appears.
Default: 140°F [60°C].
NOTICE
The DHW Boiler Setpoint will automatically be set 28°F
[15°C] higher than the DHW Storage Setpoint setting
DHW Priority Timeout prompts to enter an optional time limit that
a domestic hot water call has priority over central heating call.
Touch the
or
soft keys to adjust the timeout value, if required,
then touch
to store the setting and complete the DHW EZ Setup.
Defau
lt: Off